No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x28000013 Incorrect Connection of the SLIM Cable (Cable, Major Alarm)

ALM-0x28000013 Incorrect Connection of the SLIM Cable (Cable, Major Alarm)

Description

Alarm message:

The SLIM cable to arg1 on arg2 is not properly connected. 

This alarm is generated when the SLIM cable between the mainboard and the PCIe device is not properly connected.

Alarm object: cable

Attribute

Alarm ID Alarm Severity Auto Clear

0x28000013

Major

Yes

Parameters

Name Meaning

arg1

Device to which the SLIM cable is connected, for example, RiserCard.

arg2

Serial number of the port on the device connected by the SLIM cable. For example, PORTA, PORTB, PORTC, or PORTD.

Impact on the System

The PCIe device connected by the SLIM cable cannot be identified.

Possible Causes

  • The SLIM cable is not properly connected.
  • The SLIM cable is faulty.

Procedure

  1. Check whether the SLIM cable is properly connected.

    For details about the connection of the SLIM cable, see the user guide of the server you use.

    • If yes, go to 3.

    • If no, go to 2.

  2. Connect the SLIM cable securely. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Replace the SLIM cable. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact Huawei technical support.
Download