Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x01000001 Memory Overtemperature (Memory, Major Alarm)

ALM-0x01000001 Memory Overtemperature (Memory, Major Alarm)

Description

Alarm message:

Temperature of the DIMMs connected to CPU arg1 is too high (SN: arg2, PN: arg3).
NOTE:

From iBMC V316, the CPU and disk alarms will also include the SN and part umber and the mainboard and memory alarms will also include the part number.

This alarm is generated when the temperature of the dual in-line memory module (DIMM) connected to a CPU exceeds the overtemperature major threshold. This alarm is cleared when the temperature is within the normal range.

Alarm object: memory

Attribute

Alarm ID Alarm Severity Auto Clear

0x01000001

Major

Yes

Parameters

Name Meaning

arg1

Socket No. of the CPU.

arg2

Memory serial number.

arg3

Part number.

Impact on the System

Overheating affects memory and server performance.

Possible Causes

  • A fan module is faulty.

  • The equipment room temperature exceeds the normal range.

  • The air inlet or outlet is blocked.

  • A DIMM is faulty.

Procedure

  1. Check whether there are fan module alarms.

    • If yes, go to 2.

    • If no, go to 3.

  2. Replace the faulty fan or fan module. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Check whether the equipment room temperature exceeds the normal range.

    • If yes, go to 4.

    • If no, go to 5.

  4. Reduce the equipment room temperature to the normal range. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 5.

  5. Check whether the air inlet or outlet of the server is blocked.

    • If yes, go to 6.

    • If no, go to 7.

  6. Clear the blockage. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 7.

  7. Replace the faulty DIMMs, and power on the server. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 8.

  8. Contact Huawei technical support.