FusionServer Pro Rack Server iBMC Alarm Handling 30

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x24000003 Failed to Read CPU Board Temperature (CPU Board, Minor Alarm)

ALM-0x24000003 Failed to Read CPU Board Temperature (CPU Board, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the CPU board arg1 temperature.

This alarm is generated when the system failed to obtain the CPU board temperature.

Alarm object: CPU board

Attribute

Alarm ID Alarm Severity Auto Clear

0x24000003

Minor

Yes

Parameters

Name Meaning

arg1

Slot number of the CPU board.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

  • The iBMC is abnormal.
  • The CPU board is faulty.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Remove the power cable to power off the server, and then reconnect the power cable to power on the server. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Replace the CPU board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact Huawei technical support.