FusionServer Pro Rack Server iBMC Alarm Handling 30

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x06000017 RAID Card Overtemperature (RAID Card, Major Alarm)

ALM-0x06000017 RAID Card Overtemperature (RAID Card, Major Alarm)

Description

Alarm message:

The RAID controller card arg1 temperature (arg2 degrees C) exceeds the overtemperature threshold (arg3 degrees C) (SN: arg5, PN: arg6). 
NOTE:

From iBMC V328, the RAID controller card and PSU alarms will also include the SN and BOM code, and the fan alarms will also include the BOM code.

This alarm is generated when the temperature of the RAID controller card exceeds the overtemperature minor threshold.

Alarm object: RAID card

Attribute

Alarm ID Alarm Severity Auto Clear

0x06000017

Major

Yes

Parameters

Name Meaning

arg1

Slot number of the RAID controller card.

arg2

Current reading of the sensor.

arg3

Alarm threshold.

arg4

Front I/O module or compute module and its slot number, for example, FM or CMn.

arg5

SN of the RAID controller card.

arg6

Part number.

Impact on the System

Overheating causes RAID controller card faults and affects disk services.

Possible Causes

  • The equipment room temperature exceeds the normal range.

  • The fan speed is too low.
  • The air inlet or outlet is blocked.

  • There are unpopulated slots for blades.

Procedure

  1. Check whether there are fan module alarms.

    • If yes, go to 2.

    • If no, go to 3.

  2. Replace the faulty fan or fan module. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Check whether the equipment room temperature exceeds the normal range.

    • If yes, go to 4.

    • If no, go to 5.

  4. Reduce the equipment room temperature to the normal range. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 5.

  5. Check whether the air inlet or outlet of the server is blocked.

    • If yes, go to 6.

    • If no, go to 7.

  6. Clear the blockage. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 7.

  7. Replace the faulty RAID controller card. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 8.

  8. Contact Huawei technical support.
Download