FusionServer Pro Rack Server iBMC Alarm Handling 30

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x08000073 PCIe Card Component Absent (PCIe Card, Minor Alarm)

ALM-0x08000073 PCIe Card Component Absent (PCIe Card, Minor Alarm)

Description

Alarm message:

The arg1 PCIe card arg2 (arg3) arg4 is absent.

This alarm is generated when the PCIe card cannot be detected.

Alarm object: PCIe card

Attribute

Alarm ID Alarm Severity Auto Clear

0x08000073

Minor

Yes

Parameters

Name Meaning

arg1

Location of the PCIe card, for example, GpuBoard or Riser.

arg2

Slot number of the PCIe card, for example, 1 or 2.

arg3

PCIe card name, for example, SDI or NIC.

arg4

PCIe card component name, for example, NetCard or TransformCard.

Impact on the System

The PCIe card is malfunctioning.

Possible Causes

  • The PCIe card component is not installed.

  • The power cable is not properly connected.

Procedure

  1. Check whether the PCIe card component is installed.

    • If yes, go to 3.

    • If no, go to 2.

  2. Install the PCIe card component. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Check whether the power cable is properly connected.

    • If yes, go to 5.

    • If no, go to 4.

  4. Connect the power cable properly and check whether the alarm has been cleared.

    • If yes, no further action is required.

    • If no, go to 5.

  5. Replace the component. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 6.

  6. Contact Huawei technical support.
Download