Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2100FFFF Fault Status (BkpC MISC Cable)

ALM-0x2100FFFF Fault Status (BkpC MISC Cable)

Description

Alarm message:

Fault status

This alarm is generated when the sensor detects that the MISC signal cable to hard disk backplane C on the server with 24 hard disks is faulty.

This alarm applies only to the RH8100 V3 only.

Sensor triggering the alarm: BkpC MISC Cable

Attribute

Alarm ID Alarm Severity Auto Clear

0x2100FFFF

Major

Yes

Impact on the System

The hard disks cannot be used properly.

Possible Causes

  • The connection is abnormal between the hard disk backplane and the mainboard.
  • The hard disk backplane fails.

Procedure

  1. Restart the server. Then check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Remove the cables from the hard disk backplane, and then reconnect the cables. Check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Contact Huawei technical support.