Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0000003B Failed to Read CPU DTS Temperature (CPU, Minor Alarm)

ALM-0x0000003B Failed to Read CPU DTS Temperature (CPU, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the DTS temperature for CPU arg1 (SN: arg2, PN: arg3).
NOTE:

From iBMC V316, the CPU and disk alarms will also include the SN and part umber and the mainboard and memory alarms will also include the part number.

This alarm is generated when the system failed to obtain the DTS temperature of a CPU.

Alarm object: CPU

Attribute

Alarm ID Alarm Severity Auto Clear

0x0000003B

Minor

Yes

Parameters

Name Meaning
arg1

Socket NO. of the CPU.

arg2

CPU serial number.

arg3

Part number.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

  • The iBMC is faulty.
  • The mainboard is faulty.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact Huawei technical support.