FusionServer Pro Rack Server iBMC Alarm Handling 30

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0600000D Failed to Read RAID Controller Card Temperature (RAID Card, Minor Alarm)

ALM-0x0600000D Failed to Read RAID Controller Card Temperature (RAID Card, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the arg2 RAID controller card arg1 temperature (SN: arg3, PN: arg4). 
NOTE:

From iBMC V328, the RAID controller card and PSU alarms will also include the SN and BOM code, and the fan alarms will also include the BOM code.

This alarm is generated when the system failed to obtain the RAID controller card temperature.

Alarm object: RAID card

Attribute

Alarm ID Alarm Severity Auto Clear

0x0600000D

Minor

Yes

Parameters

Name Meaning

arg1

Slot number of the RAID controller card.

arg2

Front I/O module or compute module and its slot number, for example, FM or CMn.

arg3

SN of the RAID controller card.

arg4

Part number.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

  • The iBMC is abnormal.
  • The RAID controller card is faulty.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Remove the power cable to power off the server, and then reconnect the power cable to power on the server. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Replace the RAID controller card. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact Huawei technical support.