FusionServer Pro Rack Server iBMC Alarm Handling 31

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x32000005 Rapid Increase of PHY Bit Errors on the Link Between the Expander Controller and the RAID Controller Card (Expander, Major Alarm)

ALM-0x32000005 Rapid Increase of PHY Bit Errors on the Link Between the Expander Controller and the RAID Controller Card (Expander, Major Alarm)

Description

Alarm message:

The PHY bit errors of the link between arg1 and arg2 (arg3arg4) increased too fast.

This alarm is generated when the data is transmitted on the link between the RAID controller card and the expander controller and the PHY bit errors increase rapidly.

Expander controllers of different servers are located on different components, such as drive backplanes, mainboards, and GPU boards. For details, see the user manual of each server.

Alarm object: expander

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x32000005

Major

Yes

Parameters

Name

Meaning

arg1

RAID controller card that communicates with the expander controller, for example, RAID Card1.

arg2

Component where the expander controller related to the alarm is located, for example, Disk BP1.

arg3

Type of the expander controller related to the alarm, for example, SAS Expander.

arg4

ID of the expander controller related to the alarm.

Impact on the System

The devices (such as the RAID controller card, expander controller, and hard drives) connected to the links are affected. The system may stop responding and data may be lost.

Possible Causes

  • The cable is not securely connected or the cable connection is incorrect.
  • The cable is faulty.
  • The component where the expander controller is located is faulty.
  • The RAID controller card is faulty.

Procedure

  1. Reconnect the cable between the RAID controller card and the component where the expander controller is located, and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 2.

  2. Replace the cable, and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Replace the component where the expander controller is located, and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 4.

  4. Replace the RAID controller card related to the alarm, and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Contact Huawei technical support.