Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2C000037 CPUs Mismatch (System, Critical Alarm)

ALM-0x2C000037 CPUs Mismatch (System, Critical Alarm)

Description

Alarm message:

Different CPU models detected during system startup. 

This alarm is generated when CPUs of different models are installed in the server.

Alarm object: system

Attribute

Alarm ID Alarm Severity Auto Clear

0x2C000037

Critical

Yes

Parameters

Name Meaning

-

-

Impact on the System

The system cannot start.

Possible Causes

CPUs of different models are installed on the server.

Procedure

  1. Check whether the server is configured with different models of CPUs.

    • If yes, go to 2.
    • If no, go to 3.

  2. Use the same model of CPUs. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Switch the CPU with a functioning CPU in the same chassis, and check whether the alarm is still generated for this CPU.

    • If yes, go to 4
    • If no, go to 5

  4. Replace the CPU. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  6. Contact Huawei technical support.