Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0D000009 Power Supply Module Fault on LOM (NIC, Major Alarm)

ALM-0x0D000009 Power Supply Module Fault on LOM (NIC, Major Alarm)

Description

Alarm message:

The power supply arg1 of arg2 arg3 is abnormal.

This alarm is generated when the power supply module on the specified LOM is faulty. This alarm is cleared when the power supply module is restored.

Alarm object: NIC

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0D000009

Major

Yes

Parameters

Name

Meaning

arg1

Power supply module on the LOM, for example, (PG_3V3) or (PG_VCORE).

arg2

Slot No. of the LOM, for example NIC1.

arg3

Type of the LOM, for example (SM380).

Impact on the System

The LOM is malfunctioning, and the LOM services are affected.

Possible Causes

  • The iBMC module is faulty.
  • The LOM is faulty.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 2.

  2. Replace the NIC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Contact Huawei technical support.
Download