MA5600T, MA5603T, and MA5608T Hardware Description 25

This manual describes the Huawei MA5600T, MA5603T, and MA5608T hardware specifications, such as dimensions, weight, power consumption, capacity, structure, chassis, slots, boards, power modules, and optical modules.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SCU Boards Comparison

SCU Boards Comparison

All SCU boards support the functions as below:

  • System control and management unit
  • Active/standby switchover
  • Local and remote maintenance through maintenance serial port CON or maintenance Ethernet port ETH
  • Environmental monitoring through environment monitoring serial port ESC

In the table, "Yes" indicates "supported" and "No" indicates "not supported".

Table 3-7  Major differences between SCU boards

Board

Access Service

Daughter Board

Load sharing

Ethernet synchronization

Temperature querying and high temperature alarming

Built-in 2GB CF card

Centric Management for GE Remote Extended Subracks

D-CCAP

H801SCUB/H802SCUB

Copper

H801FLBA

H801CKMC

H801CKMD

No

No

Yes

No

No

No

H801SCUF

Optical and copper

H801FLBA

H801CKMC

H801CKMD

No

No

Yes

No

No

No

H801SCUL

Optical

H801CKMC

H801CKMD

No

No

Yes

No

No

No

H801SCUN

Optical and copper

H801FLBA

H801CKMC

H801CKMD

H801M2XA

Yes (supported in V800R011C00 and later versions)

No

Yes

No

Yes

No

H802SCUN

Optical and copper

H801FLBA

H801CKMC

H801CKMD

H801M2XA (version B)

Yes (supported in V800R011C00 and later versions)

No

Yes

No

Yes

No

H801SCUK

Optical and copper

H801FLBA

H801CKMC

H801CKMD

H801M2XA (version B)

Yes (supported in V800R011C00 and later versions)

No

Yes

No

Yes

No

H801SCUH

Optical and copper

No

Yes

Yes

Yes

Yes

No

No

H801SCUV

Optical

No

Yes

Yes

Yes

Yes

No

Yes

NOTE:
H801SCUN and H802SCUN are slot compatible.
Table 3-8  Ports of SCU boards

Board

Panel ports

Internal interfaces

Channel to the service board

Channel to the GIU board

Channel to the standby control board

Note

H801SCUB/H802SCUB

4 GE ports

16 GE channels

  • Providing four GE ports for upstream transmission using the control board or upstream board, which is controlled by the electronic switch.
  • Providing four GE ports for upstream transmission using the upstream board. Either the last GE port or VoIP daughter board can be used for upstream transmission, which is controlled by the electronic switch.

-

-

H801SCUF

4 GE ports

16 GE channels

Provides four GE channels and one 10GE channel for each upstream slot

-

Reserves two 10GE channels (not available currently) for the MPLS daughter board.

H801SCUL

None

16 GE/10GE channels

  • Providing two GE/10GE ports for upstream transmission using the upstream board.
  • Providing two GE/10GE ports for upstream transmission using the upstream board. Either the last GE/10GE port or daughter board can be used for upstream transmission, which is controlled by the electronic switch.

-

-

H801SCUN

4 GE ports

16 GE/10GE channels

Providing two GE/10GE channels for each upstream boards

Providing two 10GE channels for load sharing with the standby H801SCUN board (supported in V800R011C00 and later versions)

-

H802SCUN

4 GE ports

16 GE/10GE channels

Providing two GE/10GE channels for each upstream boards

Providing two 10GE channels for load sharing with the standby H802SCUN board (supported in V800R011C00 and later versions)

-

H801SCUK

4 GE ports

16 GE/10GE channels

Providing two GE/10GE channels for each upstream boards

Providing two 10GE channels for load sharing with the standby H801SCUK board (supported in V800R011C00 and later versions)

-

H801SCUH

4 GE/10GE ports, Supporting automatic switching for remote software commissioning using GE upstream transmission.

16 10GE/20GE channels

Providing two 10GE channels for each upstream boards

Providing two 20GE channels for load sharing with the standby H801SCUH board

-

H801SCUV

4 GE/10GE ports, Supporting automatic switching for remote software commissioning using GE upstream transmission.

16 10GE/20GE channels

Providing two 10GE channels for each upstream boards

Providing two 20GE channels for load sharing with the standby H801SCUV board

-

Download
Updated: 2019-03-18

Document ID: EDOC1000060621

Views: 136960

Downloads: 3382

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next