MA5600T, MA5603T, and MA5608T Hardware Description 25

This manual describes the Huawei MA5600T, MA5603T, and MA5608T hardware specifications, such as dimensions, weight, power consumption, capacity, structure, chassis, slots, boards, power modules, and optical modules.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ADSL2&POTS Combo Board Comparison

ADSL2&POTS Combo Board Comparison

In the table, "Yes" indicates "supported" and "No" indicates "not supported".

ADSL2+ Specifications Comparison

Table 3-40  Specifications lists of 48-channel ADSL2+ service boards

Specifications

H80BCAME

H806CAME

Applicable Line

ADSL2+ over POTS

ADSL2+ over POTS

Physical Layer Retransmission (G.INP)

Yes (Supported by V800R009C00 and later)

No

ADSL2+ Bonding

Yes

No

INM

Yes

No

SELT

Yes

Yes

xDSL MELT

No

No

Annex Type

  • G.992.1 Annex A
  • G.992.3 Annex A/L/M (EU32-EU64)
  • G.992.5 Annex A/M (EU32-EU64)
  • G.992.1 Annex A
  • G.992.3 Annex A/L/M (EU32-EU64)
  • G.992.5 Annex A/M (EU32-EU64)

Flexible Configuration Modes

Supports RFC2662, RFC4706, and TR165. (Users with a super user account can log in to the system and run the switch adsl mode to command in diagnose mode to switch between the configuration modes. The default configuration mode is RFC2662. Considering the current development trend, it is recommended that you use TR165, which is more flexible than the others)

Supports RFC2662, RFC4706, and TR165. (Users with a super user account can log in to the system and run the switch adsl mode to command in diagnose mode to switch between the configuration modes. The default configuration mode is RFC2662. Considering the current development trend, it is recommended that you use TR165, which is more flexible than the others)

Connector

Delander 64-pin

Delander 64-pin

Built-in Splitter

Yes

Yes

Temperature Query and High-temperature Alarm

Yes

Yes

Automatic Power Shutdown in Case of a High Temperature

Yes

Yes

POTS Specifications Comparison

Table 3-41  POTS Specifications lists of Combo boards

Specification

H80BCAME/H806CAME

Connector

Delander 64-pin

DSP channel (G.711)

48

Codec

G.711A

G.711U

G.729

G.723

G.726

POTS MELT

Yes

MELT precision

High

High temperature automatic shutdown

Yes

Short loop

Yes

Polarity of wires a and b

a+

b-

16/12 KC

No

Powering on/off by command

Yes

Polarity reversal

Yes

Power supply at high voltage (for a long distance)

Yes

Port current

20 mA/25 mA/30 mA