MA5600T, MA5603T, and MA5608T Hardware Description 25

This manual describes the Huawei MA5600T, MA5603T, and MA5608T hardware specifications, such as dimensions, weight, power consumption, capacity, structure, chassis, slots, boards, power modules, and optical modules.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
H801VSNF Board Description

H801VSNF Board Description

The H801VSNF is a 48-port VDSL2 over POTS splitter board that supports real impedance (600 ohms). It separates 48 channels of VDSL signals from POTS signals. The separated VDSL2 signals are transmitted to the VDSL2 service board, and the separated POTS signals are transmitted to the PSTN switch device.

Functional Specifications

The H801VSNF board supports the following function:

  • Separating 48-channel VDSL2 signals from POTS signals
  • Real impedance (600 ohms)

Figure 3-159 shows the external connections of the H801VSNF board.

Figure 3-159  External connections of the H801VSNF board

Technical Specifications

Table 3-209  Technical specifications of the H801VSNF board

Board

Dimensions (W x D x H)

Maximum Power Consumption

H801VSNF

22.86 mm x 237.00 mm x 395.40 mm

0 W

Working Principle

The H801VSNF board consists of two parts: splitter module and protection module. The splitter module separates the VDSL signals and the POTS signals. The protection module supports the over-voltage protection of the LINE line.

Front Panel Port



  • When cables from the PSTN and LINE ports are routed to an outdoor environment, the MDF must be installed with a protective unit.
  • When cables from the LINE port are routed to the user side, the MDF must be installed with a protective unit.
  • The PSTN port must be connected to an MDF with a protective unit or a POTS device. Otherwise, when the LINE port is struck by lightning, energy inside the SPL board or unit fluctuates and overlaps, which may damage the LINE port.

Pin Assignments

The pin assignment of the xDSL port, LINE port, and PSTN port on the H801VSNF board are the same. For pin assignment of the xDSL0 port, see Table 3-210; for pin assignment of the xDSL1 port, see Table 3-211.

Table 3-210  Pin assignments of the xDSL0 port

Pin

Signal

 

Pin

Signal

Port

Pin

Signal

 

Pin

Signal

1

7

 

17

15



33

23

 

49

-

2

18

34

50

3

6

19

14

35

22

51

-

4

20

36

52

5

5

21

13

37

21

53

-

6

22

38

54

7

4

23

12

39

20

55

-

8

24

40

56

9

3

25

11

41

19

57

-

10

26

42

58

11

2

27

10

43

18

59

-

12

28

44

60

13

1

29

9

45

17

61

-

14

30

46

62

15

0

31

8

47

16

63

-

16

32

48

64

Table 3-211  Pin assignments of the xDSL1 port

Pin

Signal

 

Pin

Signal

Port

Pin

Signal

 

Pin

Signal

1

31

 

17

39



33

47

 

49

-

2

18

34

50

3

30

19

38

35

46

51

-

4

20

36

52

5

29

21

37

37

45

53

-

6

22

38

54

7

28

23

36

39

44

55

-

8

24

40

56

9

27

25

35

41

43

57

-

10

26

42

58

11

26

27

34

43

42

59

-

12

28

44

60

13

25

29

33

45

41

61

-

14

30

46

62

15

24

31

32

47

40

63

-

16

32

48

64