Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Can the Lower Enclosure Frame of a CloudEngine 12800 Series Switch Be Removed?

Can the Lower Enclosure Frame of a CloudEngine 12800 Series Switch Be Removed?

Removing the lower enclosure frame is not recommended.

If the following conditions occur during installation of a CloudEngine 12800 series switch, you can remove the lower enclosure frame:

  • If the chassis cannot be moved into the cabinet with the lower enclosure frame on the chassis, remove the lower enclosure frame before placing the chassis into the cabinet.

    After 2/3 of the chassis is in the cabinet, install the lower enclosure frame back to the chassis (for installing the air filter door), and then move the chassis completely in the cabinet.

  • If the cabinet is not deep enough for the switch, determine whether the distance between the front mounting rails and the front door meets the switch installation requirement. For details, see What Requirements Should Cabinets for the CE Series Switches Meet?. If the front door cannot be closed after the switch is installed in the cabinet, remove the lower enclosure frame from the chassis.

    If lower enclosure frame is removed because the cabinet depth is small, the chassis header and cable management frames cannot be installed either. Without cable management frames, cables cannot be properly routed. This may affect normal service operations. Therefore, use a qualified cabinet for the CloudEngine 12800 series switches.

Translation