Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Common Causes

Common Causes

This fault is commonly caused by one of the following:

  • The MSDP peer to initiate SA messages is not configured on the RP.

  • The logical RP is not configured on the devices to be deployed with anycast RP or the configurations of the logical RP are incorrect.

  • The MSDP peer relationships are not set up between every two members in a mesh group.

  • The intra-domain multicast protocol used is not PIM-SM.

  • The RPF route to the multicast source is incorrect; for example, the unicast route has a loop.

  • The configurations are incorrect; for example, the configurations of the SA policy, import policy, TTL, switchover threshold, or multicast boundary are incorrect.