Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Many Times Member Switches Need to Restart If Two CE5850EIs Set Up a Stack?

How Many Times Member Switches Need to Restart If Two CE5850EIs Set Up a Stack?

Each member switch needs to restart only once to set up a stack. Perform the following operations in sequence:
  1. Complete the stack configuration of the master switch, save the configuration, and then restart the switch.
  2. Complete the stack configuration of the standby switch, save the configuration, and then power off the switch.
  3. Connect the master and standby switches using stack cables, and then power on the standby switch.
Translation