Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
What Does it Mean When an Indicator Is Yellow on a Card of CloudEngine 12800 and 12800E Series Switches?

What Does it Mean When an Indicator Is Yellow on a Card of CloudEngine 12800 and 12800E Series Switches?

Table 22-18 describes the yellow indicators on various cards of CloudEngine 12800 and 12800E series switches.

Table 22-18 Yellow indicators on cards of CloudEngine 12800 and 12800E series switches

Card Name

Indicator

Color

Description

MPU

RUN/ALM: running status indicator

Yellow

Steady on: The card is in power-off state. (For example, the card has been forcibly powered off using the power off command or is about to start.)

SFU

CMU

LPU

RUN/ALM: running status indicator

Yellow

  • Steady on: The card is in power-off state. (For example, the card has been forcibly powered off using the power off command or is about to start.)
  • Blinking: When the card is installed in the CE12804/CE12808/CE12812/CE12816 chassis, you can run the set device id-led { on | off } [ slot slot-id ] command in the diagnostic view to configure the PWR, FAN, SFU, and MPU indicators on the chassis header and RUN/ALM indicator of the card to blink yellow simultaneously. In this way, maintenance personnel can quickly find the chassis and card.

Service port indicator

Yellow

Blinking: The port is transmitting or receiving data.