No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade
Troubleshooting Guide
CloudEngine 16800, 12800, 12800E, 8800, 7800, 6800, and 5800 Series Switches
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Many Member Ports Does a Stack Require?

How Many Member Ports Does a Stack Require?

On CE12800, CE12800E, and CE16800 series switches, you can configure 1 to 32 member ports for stack connections. On CE8800, CE7800, CE6800, and CE5800 series switches, you can configure 1 to 16 member ports for stack connections.

Member switches require at least one member port to set up a stack. To improve reliability, it is recommended that two or more member ports be used to set up a stack.

Translation
Download
Updated: 2020-01-07

Document ID: EDOC1000060766

Views: 661838

Downloads: 3050

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next