Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Can I Log In to a Switch That Fails the DAD Competition Through Its Management Network Port?

Can I Log In to a Switch That Fails the DAD Competition Through Its Management Network Port?

If a backup IP address has been configured for a switch that fails the DAD competition, you can log in to the switch through its management network port. If no backup IP address is configured for a switch that fails the DAD competition, its management network port will be disabled.

Configure a backup IP address for a switch.
<HUAWEI> system-view
[~HUAWEI] interface meth 0/0/0
[~HUAWEI-MEth0/0/0] dual-active backup ip address 192.168.1.175 24 member all
[*HUAWEI-MEth0/0/0] commit