Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Common Causes

Common Causes

This fault commonly results from one of the following causes:

  • The outgoing interface is not enabled with RIP.

  • The outgoing interface is not in Up state.

  • The silent-interface command is configured on the outgoing interface to suppress the interface from sending the RIP packet.

  • The undo rip output command is configured on the outgoing interface to disable the interface from sending the RIP packet.

  • The policy filtering the imported RIP route is configured in RIP.

  • The physical status of the interface is Down or Administratively Down, or the current status of the protocol on the outgoing interface is Down. The IP address of the interface cannot be added to the advertised routing table of RIP.

  • The outgoing interface does not support the multicast or broadcast mode and a packet needs to be sent to the multicast or broadcast address.

  • The number of received routes exceeds the upper limit.

  • The configured maximum RIP packet length is less than the length of RIP packets sent by the interface.