Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Can I Use MIB to Obtain the Number of Packets Discarded by an Interface?

Can I Use MIB to Obtain the Number of Packets Discarded by an Interface?

You can use MIB to obtain the number of packets discarded by an interface of CloudEngine series switches. The objects with the OIDs 1.3.6.1.2.1.2.2.1.13 and 1.3.6.1.2.1.2.2.1.19 indicate the number of packets discarded in the inbound and outbound directions of an interface respectively.

For CloudEngine 12800 and 12800E series switches, pay attention to the following points:
  • In versions earlier than V100R005C00, the number of discarded packets obtained through MIB is always 0 to improve the NMS monitoring and query performance.
  • In V100R005C00 and later versions, you can run the set if-mib discard-statistics enable command in the system view to enable the function of using MIB to collect statistics about packets discarded by an interface.