Troubleshooting Guide

CloudEngine 16800, 12800, 12800E, 8800, 7800, 6800, and 5800 Series Switches

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Troubleshooting Procedure

Troubleshooting Procedure

After commands are configured to troubleshoot faults, pay attention to the configuration validation mode to ensure that the configurations take effect. Unless otherwise specified, this manual defaults to the two-phase validation mode.

  • In immediate validation mode, the configuration takes effect immediately after you run a command and press Enter.
  • In two-phase validation mode, you must run the commit command after commands are configured to commit the configuration.

Save the results of each troubleshooting step, so you can provide related information to Huawei technical support if your troubleshooting fails.

Procedure

  1. Check the interface type.

    Run the display this command in the interface view to check the interface type.

    • If no interface type is displayed, the default access is used. Run the port link-type command to change the interface type to trunk or hybrid.

    • If the interface type is trunk or hybrid, go to Step 2.

  2. Check whether the interface is added to a non-TRILL VLAN.

    Run the display this command in the interface view to check configurations on the interface.

    • If the interface is added to a non-TRILL VLAN, delete the VLAN.

    • If the interface is not added to a non-TRILL VLAN, go to Step 3.

  3. Collect the following information and contact technical support personnel.

    • Results of the preceding troubleshooting procedure
    • Configuration files, log files, and alarm files of the devices