Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Do I Perform a Master/Standby Switchover in a Stack?

How Do I Perform a Master/Standby Switchover in a Stack?

You can manually trigger a master/standby switchover in a stack if the current roles of member switches do not meet your requirement. For example, you can perform a master/standby switchover to change the roles after a restart or restore the original roles after an upgrade.

The following example describes the master/standby switchover on a CE8800, CE7800, CE6800, and CE5800.
<HUAWEI> display switchover state      //Check whether the stack meets switchover requirements.
   Switchover State  :  Ready          //You can perform a master/standby switchover only when the stack is ready for the switchover.
   Switchover Policy :  Board Switchover
   MainBoard         :  1
   SlaveBoard        :  2
<HUAWEI> system-view
[~HUAWEI] slave switchover enable      //Enable the switchover function.
[*HUAWEI] commit
[~HUAWEI] slave switchover             //Perform a master/standby switchover.
Warning: This operation will switch the slave board to the master board. Continue? [Y/N]: y