Troubleshooting Guide

CloudEngine 16800, 12800, 12800E, 8800, 7800, 6800, and 5800 Series Switches

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Why Is There a Great Time Difference Between the NTP Client and the NTP Server After NTP Clock Synchronization?

Why Is There a Great Time Difference Between the NTP Client and the NTP Server After NTP Clock Synchronization?

The reason is that a time zone is configured on the NTP client or server. NTP cannot synchronize the time zone setting. For example, if Beijing time (UTC + 8) is set to the NTP server while the NTP client adopts the default UTC time, after NTP clock synchronization, the time of the NTP server will be eight hours earlier than that of the NTP client.

You are advised to set the same time zone for the NTP server and client. Otherwise, the NTP server time and client time may differ greatly after NTP clock synchronization.