Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Do I Change a Stack from the LPU Connection Mode to MPU Connection Mode?

How Do I Change a Stack from the LPU Connection Mode to MPU Connection Mode?

Perform the following operations to change a stack from the LPU connection mode to MPU connection mode:

  1. Connect SIP ports on MPUs to meet cable connection requirements of the MPU connection mode.

  2. Run the stack member all link-type mainboard-direct command to change the stack connection mode to MPU connection.

    <HUAWEI> system-view
    [~HUAWEI] stack
    [~HUAWEI-stack] stack member all link-type mainboard-direct
    [*HUAWEI-stack] commit
    
  3. Save the configuration and then restart the stack to make the configuration take effect.