Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Why External Routes Imported by OSPF on CE Series Switches Cannot Be Viewed in the Routing Table?

Why External Routes Imported by OSPF on CE Series Switches Cannot Be Viewed in the Routing Table?

This problem is caused by routing loop detection. By default, routing loop detection is enabled on CE switches. When OSPF VPN multi-instance is deployed on a Multi-VPN-Instance CE (MCE) device, and DN Bit is set in Type 3, Type 5, or Type 7 LSAs, corresponding routes cannot be calculated and viewed in the routing table because routing loop detection will be performed during OSPF route calculation. To address this problem, run the vpn-instance-capability simple command on the MCE to disable routing loop detection in the OSPF instance.

Translation
Download
Updated: 2020-01-07

Document ID: EDOC1000060766

Views: 608190

Downloads: 2951

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next