Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Are Power Module Slots Distributed in a CE Series Switch?

How Are Power Module Slots Distributed in a CE Series Switch?

CloudEngine 12800 and 12800E

Slot layout in the CloudEngine 12800 and 12800E series switches

Chassis Model

Front

Rear

Figure ID

CE12804 chassis

2 MPU slots, 2 CMU slots, 4 LPU slots, and 4 power module slots

6 SFU slots, 9 fan module slots, and a power distribution unit

Figure 22-8

CE12808 chassis

2 MPU slots, 2 CMU slots, 8 LPU slots, and 8 power module slots

6 SFU slots, 13 fan module slots, and a power distribution unit

Figure 22-9

CE12812 chassis

2 MPU slots, 2 CMU slots, 12 LPU slots, and 12 power module slots

6 SFU slots, 17 fan module slots, and a power distribution unit

Figure 22-10

CE12816 chassis

2 MPU slots, 2 CMU slots, 16 LPU slots, and 20 power module slots

6 SFU slots, 23 fan module slots, and a power distribution unit

Figure 22-11

CE12804S chassis

2 MPU slots, 2 SFU slots, 4 LPU slots, and 4 power module slots

3 fan module slots and a power distribution unit

Figure 22-12

CE12808S chassis

2 MPU slots, 4 SFU slots, 8 LPU slots, and 8 power module slots

6 fan module slots and a power distribution unit

Figure 22-13

CE12804E chassis

2 MPU slots, 4 LPU slots, and 4 power module slots

6 SFU slots and 6 single-fan module slots

Figure 22-14

CE12808E chassis

2 MPU slots, 8 LPU slots, and 8 power module slots

6 SFU slots, 2 four-fan assembly module slots, and 3 single-fan module slots

Figure 22-15

CE12816E chassis

2 MPU slots, 16 LPU slots, and 10 power module slots

6 SFU slots, 4 four-fan assembly module slots, and 5 single-fan module slots

Figure 22-16

  • In N+N backup mode, power module (PM) slots in the chassis are divided into area A and area B, and power modules in the two areas work as a hot backup for each other.
  • MPU: Main Processing Unit
  • SFU: Switch Fabric Unit
  • CMU: Centralized Monitoring Unit
  • LPU: Line Processing Unit
  • PM: power module
  • FAN: fan module
Figure 22-8 Slot layout in the CE12804 chassis
Figure 22-9 Slot layout in the CE12808 chassis
Figure 22-10 Slot layout in the CE12812 chassis
Figure 22-11 Slot layout in the CE12816 chassis
Figure 22-12 Slot layout in the CE12804S chassis
Figure 22-13 Slot layout in the CE12808S chassis
Figure 22-14 Slot layout in the CE12804E chassis
Figure 22-15 Slot layout in the CE12808E chassis
Figure 22-16 Slot layout in the CE12816E chassis

CloudEngine 8800, 7800, 6800, and 5800

On the front panel of the CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE6850HI, CE6855-48T6Q-HI, CE6856-48T6Q-HI, CE6850U-HI, CE6857EI, CE6875EI, CE8860EI, CE8861EI, and CE8868EI), the slots at two sides are power module slots, and the two slots in the middle are fan module slots, as shown in Figure 22-17.

Figure 22-17 Front panel of the CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE6850HI, CE6855-48T6Q-HI, CE6856-48T6Q-HI, CE6850U-HI, CE6857EI, CE6875EI, CE8860EI, CE8861EI, and CE8868EI)

Figure 22-18 shows the slots on the front panel of the CE6850HI, CE6855-48T6Q-HI, CE6856-48T6Q-HI, CE6850U-HI, and CE6875EI switches.

Figure 22-18 Front panel of the CE6850HI, CE6855-48T6Q-HI, CE6856-48T6Q-HI, CE6850U-HI, and CE6875EI switches

Figure 22-19 shows the slots on the front panel of the CE6857EI switch.

Figure 22-19 Front panel of the CE6857EI switch

Figure 22-20 shows the slots on the front panel of the CE8860EI, CE8861EI, and CE8868EI switches.

Figure 22-20 Front panel of the CE8860EI, CE8861EI, and CE8868EI switches

Figure 22-21 shows the slots on the front panel of the CE8850-64CQ-EI switch.

Figure 22-21 Front panel of the CE8850-64CQ-EI switch
Translation
Download
Updated: 2020-01-07

Document ID: EDOC1000060766

Views: 608519

Downloads: 2951

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next