Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Do I Configure Inter-Chassis Link Aggregation?

How Do I Configure Inter-Chassis Link Aggregation?

The following example uses CE8800, CE7800, CE6800, and CE5800 series switches. In Figure 22-74, SwitchA and SwitchB set up a stack and connect to SwitchC through inter-chassis link aggregation.
Figure 22-74 Configuring inter-chassis link aggregation
The configuration procedure is as follows:
  1. Configure an inter-chassis Eth-Trunk in the stack.
    <iStack> system-view
    [~iStack] interface eth-trunk 1
    [*iStack-Eth-Trunk1] trunkport 10ge 1/0/1
    [*iStack-Eth-Trunk1] trunkport 10ge 2/0/1
    [*iStack-Eth-Trunk1] commit
    
  2. Configure the Eth-Trunk on SwitchC.
    <SwitchC> system-view
    [~SwitchC] interface eth-trunk 1
    [*SwitchC-Eth-Trunk1] trunkport 10ge 1/0/1
    [*SwitchC-Eth-Trunk1] trunkport 10ge 1/0/2
    [*SwitchC-Eth-Trunk1] commit
    