Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
A Card Cannot Be Powered On

A Card Cannot Be Powered On

Fault Description

A card cannot be powered on, and its RUN/ALM indicator is steady yellow.

Common Causes

  • No fan modules are working for the slot where the card is installed.

  • The available power of the system is not enough for the card.

Troubleshooting Procedure

  1. Check whether fan modules are available for the slot where the card is installed. If not, install fan modules in the slots.

    Full configuration of fan modules is recommended for a switch. If fan modules for some slots are absent, cards in these slots may fail to be powered on. For example, on a CE12804 switch (see Figure 10-3), FAN1 and FAN2 work for slot 1 and slot 2. If FAN1 and FAN2 are absent, cards in slot 1 and slot 2 cannot be powered on.

    Figure 10-3 Mapping between card slots and fan modules on a CE12804 switch

  2. Use either of the following methods to check the available power on the switch:
    • Run the display device power system command to check the total power available. If the power insufficient, use more power modules.

      <HUAWEI> display device power system
      Average power consumption: 427 W
      Current power consumption: 416 W
      Power manage cycle: 1 hour
      Power manage mode: Standard
      
      Power Redundant: Non
      Total Power Capacity without Backup: 2700 W
      Total Power Capacity with Backup: 2700 W
      Total Power Allocated: 1030 W
      : 1206 W     //Power available to new modules
      Total Power reserved for MPU,SFU,CMU and FAN Board(s): 464 W
      ......
    • Use the Hardware Configuration Tool to calculate the number of power modules required. If there are not enough power modules for the switch, install more power modules.

  3. If the problem persists, contact technical support.