Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Can Member Switches with Different System Software Versions Set Up a Stack?

Can Member Switches with Different System Software Versions Set Up a Stack?

Member switches with different system software versions can set up a stack. Member switches will synchronize with the system software version of the master switch, restart, and then join the stack again.

The system software version synchronized from the master switch must be able to run on other member switches; otherwise, these member switches cannot set up a stack.

It is recommended that switches use the same system software version before they set up a stack.