Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Can I Perform an Active/Standby Switchover on CE12800 and CE12800E Switches?

How Can I Perform an Active/Standby Switchover on CE12800 and CE12800E Switches?

After an active/standby switchover is performed on CE12800 and CE12800E switches, the standby MPU becomes the new active MPU. Perform the following steps to replace the faulty switch:

<HUAWEI> system-view
[~HUAWEI] slave switchover enable      //Enable the active/standby switchover function.
[*HUAWEI] commit
[~HUAWEI] slave switchover      //Perform an active/standby switchover.