Troubleshooting Guide

CloudEngine 16800, 12800, 12800E, 8800, 7800, 6800, and 5800 Series Switches

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
General Power Module Fault Location Procedure

General Power Module Fault Location Procedure

Troubleshooting Flowchart

Figure 10-2 shows the procedure for troubleshooting a power module.

Figure 10-2 Power module troubleshooting flowchart

Procedure

  1. Use a multimeter to measure the input voltage of the power module, and check whether the input voltage is in the operating voltage range of the power module.
  2. Unplug and plug the power module and its power cable to ensure that they are securely installed.
  3. Perform a cross test over the power modules.

    Move the power module to another switch or replace it with another power module that can work normally in another switch, to determine whether the power module or the switch itself is faulty.

    • If the test proves that the power module is faulty, send the power module back for repair.
    • If the test proves that the switch is faulty, contact technical support personnel.