X6800 Server V100R003 User Guide 13

This document describes the Huawei X6800 server (X6000 for short) in terms of its appearance, features, specifications, system components, device installation, cable connections, and installation verification.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Server Node

Checking the Server Node

Scenarios

Log in to the iBMC WebUI and check the health status of the Server Node. Ensure that its health status meets the environment requirements for software installation.

Prerequisites

Conditions

The Server Node is powered on.

Data

You have obtained the following data:

  • IP address of the iBMC management network port on the Server Node
  • User name and password for logging in to the iBMC WebUI
Table 4-8 Default data

Category

Name

Default Value

iBMC management network port data

IP address and subnet mask of the management network port

The system automatically assigns default IP addresses to the management network ports on server nodes based on the slot numbers of the server nodes:

  • Default IP addresses of 4U8 server nodes:
    • Slot 1: 10.10.1.101
    • Slot 2: 10.10.1.102
    • Slot 3: 10.10.1.103
    • Slot 4: 10.10.1.104
    • Slot 5: 10.10.1.105
    • Slot 6: 10.10.1.106
    • Slot 7: 10.10.1.107
    • Slot 8: 10.10.1.108
  • Default IP addresses of 4U4 server nodes:
    • Slot 1: 10.10.1.101
    • Slot 3: 10.10.1.103
    • Slot 5: 10.10.1.105
    • Slot 7: 10.10.1.107

iBMC login data

User name and password

  • Default user name: root
  • Default password: Huawei12#$

Workflow

Check the Server Node in the sequence shown in Figure 4-26. Determine the checking method based on site requirements.

Figure 4-26 Process for checking the Server Node

Procedure

  1. Check indicator status.

    Observe Server Node indicator status, and check that the device hardware is properly operating.

    For details, see .

  2. Check the Server Node on the iBMC WebUI.

    1. Log in to the iBMC WebUI. For details, see Logging In to the iBMC WebUI or CLI of the Server Node.
    2. Choose Information on the menu bar, choose Information Summary in the navigation tree.
    3. Query Server Node version information.

      View the Server Node version information. See (1) in the Figure 4-27, check that the Server Node version information meets site requirements.

    4. Query the health status of the Server Node.

      View the Server Node health status. See (2) in the Figure 4-27.

    5. Clear alarms if any. For details, see the X6800 Server V100R003 Alarm Handling.
    Figure 4-27 Checking the Server Node