FusionServer Pro X6800 Server iBMC (Earlier Than V250) User Guide 31

This document describes the underlying management software Intelligent Baseboard Management Controller (iBMC) of the servers.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuration File Description

Configuration File Description

Table 2-72 describes the parameters in the iBMC configuration file.

Table 2-72 iBMC parameters
Type Exported parameter Exported subparameter Description
Local user User UserName Name of the user.
PassWord Password of the user.
Privilege Operation permissions assigned for the user.
UserRoleId Role of the user.
PermitRuleIds Login rules applied for the user.
LoginInterface Interfaces through which the user can log in to the iBMC.
IsUserEnable User status (enabled or disabled).
UserRole KVMMgnt Rights for KVM management.
UserMgnt Rights for user management.
VMMMgnt Rights for VMM management.
BasicSetting Rights for basic operations.
ReadOnly Read-only rights.
PowerMgnt Rights for power management.
DiagnoseMgnt Rights for debugging and diagnosis.
SecurityMgnt Rights for security management.
Two-factor authentication MutualAuthentication MutualAuthenticationState Two-factor authentication status, which can be enabled or disabled.
MutualAuthenticationOCSP Setting of two-factor authentication revocation check, which can be enabled or disabled.
LDAP configuration LDAP Enable LDAP function, which can be enabled or disabled.
CertStatus LDAP certificate verification, which can be enabled or disabled.
HostAddr LDAP server address.
Port LDAPS port number.
UserDomain Domain name.
Folder Folder in which user applications are stored.
LDAPGroup GroupName LDAP group name.
GroupFolder Application folder for an LDAP group.
GroupPermitRuleIds Login rules applied for an LDAP group.
GroupLoginInterface Login interfaces allowed for an LDAP group.
GroupPrivilege Operation permissions assigned for an LDAP group.
Security hardening PasswdSetting EnableStrongPassword Password complexity check status, which can be enabled or disabled.
SecurityEnhance SSHPasswordAuthentication SSH password authentication status, which can be enabled or disabled.
PwdExpiredTime Time when the password expires.
MinimumPwdAge Minimum validity period of the password.
ExcludeUser User who can log in to the system in an emergency.
OldPwdCount Number of previous passwords that cannot be used.
AuthFailMax Maximum number of login attempts allowed before a user account is locked.
AuthFailLockTime User account lockout period.
PermitRule TimeRuleInfo Time-based login rules.
IpRuleInfo IP-based login rules.
MacRuleInfo MAC-based login rules.
SecurityEnhance PermitRuleIds Login rule, which can be enabled or disabled.
BannerState Login security banner, which can be enabled or disabled.
BannerContent Login security banner content.
Network configuration BMC HostName iBMC host name.
EthGroup NetMode iBMC network port mode.
ActivePort Management network port specified for the iBMC.
IpVersion IP version, which can be enabled or disabled.
IpMode Mode in which IPv4 addresses are assigned.
IpAddr IPv4 address.
SubnetMask IPv4 subnet mask.
DefaultGateway Default gateway IPv4 address.
Ipv6Mode Mode in which IPv6 addresses are allocated.
Ipv6Addr IPv6 address.
Ipv6Prefix Prefix length of the IPv6 address.
Ipv6DefaultGateway Default gateway IPv6 address.
DNSSetting IPVer IP version bound with the DNS.
Mode Mode in which DNS addresses are assigned.
PrimaryDomain Preferred DNS server.
BackupDomain Alternate DNS server.
DomainName DNS domain name.
EthGroup VlanState VLAN, which can be enabled or disabled.
VlanID VLAN ID.
NTP EnableStatus NTP, which can be enabled or disabled.
Mode NTP mode.
PreferredServer Address of the preferred NTP server.
AlternativeServer Address of the alternate NTP server.
AuthEnableStatus NTP server authentication, which can be enabled or disabled.
BMC TimeZone Time zone of the iBMC.
Service configuration PortConfig State FTP, which can be enabled or disabled.
Port FTP port number.
State SSH, which can be enabled or disabled.
Port SSH port number.
Snmp State SNMP Agent, which can be enabled or disabled.
PortID SNMP Agent port number.
Kvm State KVM, which can be enabled or disabled.
Port KVM port number.
Vmm State VMM, which can be enabled or disabled.
Port VMM port number.
Video State Video, which can be enabled or disabled.
Port Video port number.
PortConfig State HTTP, which can be enabled or disabled.
Port HTTP port number.
State HTTPS, which can be enabled or disabled.
Port HTTPS port number.
RmcpConfig LanState IPMI LAN (RMCP), which can be enabled or disabled.
Port1 IPMI LAN (RMCP) port 1.
Port2 IPMI LAN (RMCP) port 2.
LanPlusState IPMI LAN (RMCP+), which can be enabled or disabled.
System configuration Snmp V1State Support for SNMPv1.
V2CState Support for SNMPv2c.
LongPasswordEnable Setting of long passwords, which can be enabled or disabled.
ROCommunity Read-only community string.
RWCommunity Read-write community string.
SNMPV1V2CPermitRuleIds SNMP login rules.
AuthProtocol SNMPv3 authentication algorithm.
PrivProtocol SNMPv3 encryption algorithm.
SecurityEnhance TLSVersion TLS version.
EnableUserMgnt User management on the OS, which can be enabled or disabled.
Session Timeout Timeout period for a web session.
Mode Web session mode.
BMC LocationInfo Location of the device.
MeInfo CpuUtiliseThre CPU usage alarm threshold.
MemUtiliseThre Memory usage alarm threshold.
Partition RAIDMode RAID working mode (RH8100 only)
System boot option Bios StartOption First boot device.
StartOptionFlag Whether the boot device is effective permanently or just for one time.
Alarm settings SyslogConfig EnableState Syslog status, which can be enabled or disabled.
MsgIdentity Syslog host identifier.
MsgSeverity Syslog alarm severity level.
NetProtocol Protocol used to transfer syslog messages.
AuthType Syslog authentication mode.
SyslogItemCfg EnableState Syslog server, which can be enabled or disabled.
DestAddr Syslog server address.
DestPort Syslog server port number.
LogSrcMask Syslog log type.
TrapConfig TrapEnable Trap status, which can be enabled or disabled.
TrapVersion Trap version.
Trapv3Userid SNMPv3 user name.
TrapMode Trap mode.
TrapIdentity Trap host identifier.
CommunityName Trap community name.
SendSeverity Severity levels of alarms to be sent through trap messages.
TrapItemCfg ItemEnable Trap server, which can be enabled or disabled.
DestIpAddr Trap server address.
DestIpPort Trap server port number.
Separator Delimiter used to separate keywords in a trap message.
Time Message content (time).
SensorName Message content (sensor name).
Severity Message content (severity level).
EventCode Message content (event code).
EventDesc Message content (event description).
ShowKeyWord Display the keywords in messages.
SmtpConfig SmtpEnable SMTP, which can be enabled or disabled.
SmtpServer SMTP server address.
TlsSendMode TLS, which can be enabled or disabled.
AnonymousMode Anonymous login, which can be enabled or disabled.
LoginName User name of the email sender.
LoginPasswd Password of the email sender.
SenderName Mailbox address of the sender.
TempletTopic Email subject.
TempletIpaddr Email subject contains the host name.
TempletBoardSn Email subject contains the board serial number.
TempletAsset Email subject contains the product asset tag.
SendSeverity Severity levels of the alarms to be sent.
SmtpItemCfg EmailName Recipient email address.
EmailDesc Information about the alarm
ItemEnable Whether alarm email notifications are sent to the recipient.
Power control Payload PowerOffTimeoutEN Power-off timeout, which can be enabled or disabled.
PowerOffTimeout Power-off timeout period.
PwrButtonLock Function of disabling the power button on the server front panel.
PowerRestorePolicy Power restore policy when power is supplied.
Power PowerCapping Enable Power capping, which can be enabled or disabled.
LimitValue Power cap value.
FailAction Function of forcibly shutting down the server if the power capping fails.
Energy saving settings SysPower ExpectedMode Power supply working mode.
ExpectedActive Active power supply.
Remote control Kvm EncryptState KVM encryption, which can be enabled or disabled.
Vmm EncryptState VMM encryption, which can be enabled or disabled.
Kvm KeyboardMode Enable or disable persistent connection of the virtual keyboard and mouse.
KvmTimeout Remote console timeout period.
LocalKVMState Local KVM, which can be enabled or disabled.
Video playback Video VideoSwitch Video recording function, which can be enabled or disabled.
Screenshot Kvm ScreenSwitch Screenshot function, which can be enabled or disabled.
Black box Diagnose BlackBoxState Black box function, which can be enabled or disabled.
Serial port data Diagnose SolDataState Serial port diagnosis function, which can be enabled or disabled.
Others PortConfig State NAT, which can be enabled or disabled.
ExPortConfig State SSDP, which can be enabled or disabled.
PortConfig Port NAT port number.
Bios BiosPrintFlag BIOS debug switch.
Cooling Mode Speed adjustment mode of fans.
Level Fan speed level.
Stateless Enable Stateless computing, which can be enabled or disabled.
SysManagerID Remote management ID for stateless computing.
AutoPowerOn Automatic power-on for stateless computing.
BroadcastNetSegment Broadcast network segment used for automatic discovery.
BroadcastPort Broadcast port number used for automatic discovery.
SysManagerIP IP address of the server that performs power control of other servers.
SysManagerPort Port number of the server that performs power control of other servers.

Table 2-73 describes the parameters in the BIOS configuration file.

Table 2-73 BIOS parameters
Parameter Description
ProcessorHyperThreadingDisable Processor hyper-threading function, which can be enabled or disabled.
ProcessorFlexibleRatioOverrideEnable Function of setting the CPU frequency upper limit. This function is disabled by default.
ProcessorFlexibleRatio Upper limit of the CPU frequency. By default, it is the nominal CPU frequency.
MonitorMwaitEnable Monitor/Mwait, which can be enabled or disabled.
ProcessorVmxEnable CPU virtualization, which can be enabled or disabled.
ProcessorLtsxEnable Intel Trusted Execution Technology (TXT), which can be enabled or disabled.
MlcStreamerPrefetcherEnable Function for setting hardware prefetcher.

Hardware prefetcher allows the CPU to prefetch instructions or data and save them to level-2 cache before processing the instructions or data. This feature reduces memory read time and eliminates potential bottlenecks.

MlcSpatialPrefetcherEnable

Function for setting adjacent cache line prefetcher.

Adjacent cache line prefetcher allows prefetch of data adjacent to the data to be read. This feature improves read speed.

DCUStreamerPrefetcherEnable

Function for setting DCU streamer prefetcher.

DCU streamer prefetcher allows CPU data to be prefetched, which reduces data read time.

DCUIPPrefetcherEnable

Function for setting DCU IP prefetcher.

DCU IP prefetcher enables the system to check historical records for the data that must be prefetched, which reduces data read time.

CustomPowerPolicy Menu for selecting the energy-saving mode.
PowerSaving Dynamic Energy Management Technology (DEMT) integrating uniBIOS frequency adjustment algorithms developed by Huawei. It can improve energy efficiency test results for servers running specific OSs.
ProcessorEistEnable

Function of enabling Enhanced Intel SpeedStep® Technology (EIST).

EIST enables CPU frequency to be dynamically adjusted based on workloads.

TurboMode CPU Turbo mode, which can be enabled or disabled.
PStateDomain P-state domain switch, which allows frequency adjustment by core or package.
ProcessorCcxEnable CPU C-state control, which controls the power consumption of CPUs in idle state.
TStateEnable CPU T-state switch. This function is not available because it limits the CPU frequency.
PackageCState Function for setting Package C state.
C3Enable Function for setting CPU C3 state.
C6Enable Function for setting CPU C6 state.
ProcessorC1eEnable Function for setting CPU C1e state.
OSCx Function for adjusting ACPI C2/C3.
QpiLinkSpeed Function for setting QPI link speed.
ClusterOnDieEn Function for setting ClusterOnDie in memory Snoop mode.
EarlySnoopEn Function for setting EarlySnoop and HomeSnoop.
DdrFreqLimit Function for setting memory frequency.
RankMargin Function for setting Rank Margin Tool.
rmtPatternLength RMT Pattern Length, which is set only when Rank Margin Tool is enabled.
MemTestOnFastBoot Memory test switch set for fast boot.
ADREn Function for setting memory ADR.
CustomRefreshRateEn Function for setting memory refresh rate.
CustomRefreshRate Memory refresh rate.
refreshMode

Memory refresh mode.

  • 1: 2x memory self-refresh.
  • 0: 2x memory self-refresh is not supported.

If this parameter is set to 1, the memory refresh rate will be doubled when the DIMM temperature exceeds 85ºC.

mcODTOverride Function for setting memory controller (MC) on die termination (ODT).

ODT allows the DRAM controller to dynamically control the termination resistance value of DQ/DQS/DM pins on DRAM devices in a variety of ways. The value can be 50 or 100 ohms.

NumaEn Function for setting Non Uniform Memory Access (NUMA).

NUMA that allows memory resources to be dynamically allocated among multiple nodes. It allows the processors to simultaneously access different memory addresses.

IsocEn Function for setting the isochronous flow-control mode.
RASMode Memory RAS mode, which can be independent, mirrored, or lockstep mode.
enableSparing Function for setting Rank Sparing.
multiSparingRanks Haswell CPU supports multiple spare ranks. The number of spare ranks can be set for a channel.
spareErrTh Memory correctable error threshold.

When the number of correctable errors reaches this threshold, an SMI will be triggered and measures will be taken based on the RAS feature configured.

PatrolScrub Function for setting memory patrol scrub.

Memory patrol scrub allows the memory engine to check the memory at a certain speed and correct the correctable errors found and prevent errors from accumulating as uncorrectable errors.

PatrolScrubDuration Memory patrol duration in hours.
DemandScrubMode Function for setting Demand Scrub.

Demand Scrub allows the HA to correct errors found when reading data, and write correct data to the memory.

DeviceTaggingMode Function for setting Device Tagging.

Device Tagging allows an SMI to be triggered when the number of errors occurred on a memory chip exceeds the threshold. During the SMI processing, a parity chip can be used to replace the faulty chip.

thermalthrottlingsupport

Memory temperature adjustment mode.

  • Closed Loop Thermal Throttling (CLTT) applies to DIMMs with temperature sensors. It allows dynamic memory adjustment based on the sensor temperature.

  • Open Loop Thermal Throttling (OLTT) applies to DIMMs without temperature sensor. It allows static memory adjustment based on configuration.

PcieAcpiHotPlugEnable IIO PCI-e hotplug, which can be enabled or disabled.
EnableAzaliaVCpOptimizationste azalia_on_vcp, which can be enabled or disabled.
PCIeSRIOVSupport PCIe virtualization, which can be enabled or disabled.
VTdSupport Intel VT for Directed I/O (VT-d), which can be enabled or disabled.
InterruptRemap Interrupt Remapping, which can be enabled or disabled.
CoherencySupport Coherency support, which can be enabled or disabled.
IsochCoherencySupport Coherency support (Isoch), which can be enabled or disabled.
IdeController SATA controller, which can be enabled or disabled.
SataCnfigure SATA controller mode.
PchsSata sSATA controller, which can be enabled or disabled.
sSataInterfaceMode sSATA controller mode.
XHCIMode Function for setting the USB 3.0 controller.
CREnable Serial port redirection, which can be enabled or disabled.
CRTerminalType Font type for serial port redirection.
CRBaudRate Baud rate for serial port redirection.
CRInfoWaitTime Time before serial port redirection initialization information is displayed.
CRAfterPost Specifies whether serial port redirection takes effect after BIOS POST.
PXE1setting Function for setting PXE of LOM 1.
PXE2setting Function for setting PXE of LOM 2.
WheaSupport WHEA, which can be enabled or disabled.
WheaEinjType WHEA error injection, which can be enabled or disabled.
SystemErrorEn Fault diagnostics, which can be enabled or disabled.
FDM Reporting of fault diagnostics to the iBMC, which can be enabled or disabled.
PoisonEn Poison bit, which can be enabled or disabled.
EMcaLogEn EMCA log (ELOG), which can be enabled or disabled.

The BIOS creates ELOG entries to record detailed error information for the OS/VMM to predict faults. The log is stored in the reserved memory provided by the BIOS and accessed through the entry address. There is also a WHEA log corresponding to ELOG, and the structure of the WHEA log is defined by ACPI specifications.

EMcaCSmiEn CMCI-to-SMI signals, which can be enabled or disabled.

If this function is disabled, only CMCI will be triggered when correctable errors are detected on the memory. An SMI will be triggered only when the number of errors reaches the threshold.

If this function is enabled, each correctable error will trigger an SMI, which is processed by the BIOS. At the end of the SMI processing function, the BIOS decides whether to send an MCE signal to the OS. This helps to collect more useful information.

PowerStateRestoreOnACLoss Power control policy for the x86 server when the AC is powered on.
  • ON: automatic power-on
  • OFF: remain power-off
  • Last State: restore the last state
BmcWdtEnable POST watch dog, which can be enabled or disabled.
BmcWdtTimeout Timeout period of the POST watch dog.
BmcWdtAction POST watch dog actions.
OSWdtEnable OS watch dog, which can be enabled or disabled.
OSWdtTimeout Timeout period of the OS watch dog.
OSWdtAction OS watch dog actions.
SysDbgLevel Function for setting BIOS debugging.
serialDebugMsgLvl Message level of BISO debugging.
Pci64BitResourceAllocation Function for setting allocation of PCI 64-bit resources.

If it is enabled, the PCI MMIO address space is greater than 4 GB.

ClkGenSpreadSpectrum Spread spectrum switch.
WakeOnPME Wake On LAN switch.
NICTrunk Before the OS starts, the DisableNic2ndhandle function will be called to disable the second optical port of 82599. This function is not available at present.
Language Language used.
ComBaseOutput Serial port IO base settings.
OemMemTurbo Memory overclock switch.
SoftRaidModeSelect SoftRAID selection switch.
BootType Boot type, which can be Legacy, UEFI, or DUAL.
QuickBoot Quick Boot, which can be enabled or disabled.

If this function is disabled, a memory test will be performed after the first screen upon each startup.

QuietBoot Function for setting display of boot information before the BIOS logo is displayed.
PXEOnly Enables the server to boot from PXE only.
VideoSelected Onboard or external video card selected.
NoBootDevCtr Whether to restart the system when no boot device is available.
BootTypeOrder[0] Boot sequence.
BootTypeOrder[1] Boot sequence.
BootTypeOrder[2] Boot sequence.
BootTypeOrder[3] Boot sequence.