Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Indicator Commands

Indicator Commands

This topic describes all indicator commands.

Querying the State of the Current Indicator (ledinfo)

Function

The ledinfo command is used to query the state of the current indicator.

Format

ipmcget -d ledinfo

Parameters

None

Usage Guidelines

None

Example

# Query the status of the indicator.

iBMC:/->ipmcget -d ledinfo
LED Name               : SysHealLed
LED Mode               : Local Control
LED State              : ON
LED Color              : GREEN
LED Color Capabilities : RED GREEN
Default LED Color in
      Local Control    : GREEN
      Override State   : GREEN

LED Name               : UIDLed
LED Mode               : Local Control
LED State              : OFF
LED Color              : BLUE
LED Color Capabilities : BLUE
Default LED Color in
      Local Control    : BLUE
      Override State   : BLUE

Setting the UID Indicator (identify)

Function

The identify command is used to set the UID indicator.

Format

ipmcset -d identify [ -v {time | force }]

Parameters

Parameter Description Value
time Indicates the duration for turning on the UID indicator.

The value is an integer, in the unit of seconds. The range is 0 to 255.

0: indicates close the led.

force Indicates turning on the UID indicator permanently. -

Usage Guidelines

If no parameter is set, the UID indicator is on for 15s by default.

Example

# Turn on the UID indicator permanently.

iBMC:/->ipmcset -d identify -v force
Identify UID led successfully.