No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CX110 Switch Module V100R001C10 User Guide 10

This document describes the features, installation, removing, and configuration methods of the CX110 GE switch module of the E9000 server.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Switching Plane

Checking the Switching Plane

Check the GE switching plane operating status of the CX110.

Procedure

  1. log in to the GE switching plane CLI.
  2. Run the following command on the CLI of the GE switching plane to check the current version of the GE switching plane:

    <HUAWEI> display version

    The command output is as follows:

    Huawei Versatile Routing Platform Software                
    VRP (R) software, Version 8.50 (OSCA V100R001C03)         
    Copyright (C) 2012-2013 Huawei Technologies Co., Ltd.     
    HUAWEI OSCA uptime is 0 day, 0 hours, 1 minutes         
                                                              
    CX110(Master) 1 : uptime is  0 day, 0 hours, 1 minutes  
            StartupTime 2013/05/16 17:43:57                 
    Memory    Size    : 2048 M bytes 
    FLASH     Size    : 1024 M bytes 
    CX110 version information          
    1. PCB      Version : CX110 VER B  
    2. MAB      Version : 0              
    3. Board    Type    : CX110          
    4. CPLD1    Version : 001            
    5. BIOS     Version : 2.42            
    6. Software Version : 1.01

    Software Version indicates the current software version.

  3. Check whether the software version is consistent with the desired one.

    • If yes, go to 4.
    • If no, contact Huawei technical support.

  4. Query the alarms of the GE switching plane.

    <HUAWEI> display alarm active

    The command output is as follows:

    1:Critical  2:Major  3: Minor  4:Warning 
    ------------------------------------------------------------------ 
    Sequence AlarmId    Level Date Time  Description                 
    ------------------------------------------------------------------     

    The parameters are described as follows:

    • Critical: critical alarm
    • Major: major alarm
    • Minor: minor alarm
    • Warning: warning alarm
    • Sequence: alarm sequence
    • AlarmId: alarm ID
    • Level: alarm severity
    • Date Time: date and time at which an alarm is generated
    • Description: alarm description

      If no information is displayed, no alarm is generated.

  5. Check whether an alarm is generated.

    • If yes, go to 6.
    • If no, no further action is required.

  6. Handle the alarm. For details, see the E9000 Server V100R001 Alarm Handling.
Translation
Download
Updated: 2019-08-09

Document ID: EDOC1000068625

Views: 18648

Downloads: 487

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next