CX110 Switch Module V100R001C10 User Guide 10

This document describes the features, installation, removing, and configuration methods of the CX110 GE switch module of the E9000 server.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Internal Chassis Networking

Internal Chassis Networking

This topic describes connection relationships between the CX110 and mezz modules on compute nodes.

For details, see E9000 Blade Server Mezz Module-Switch Module Interface Mapping Tool.

Figure 2-8 shows the internal chassis networking for the CX110 and compute nodes. Ports on compute nodes for connecting to the CX110 are provided by two mezz modules as follows:

  • Mezz 1 connects to GE switching planes of the CX110s in slots 2X and 3X.
  • Mezz 2 connects to GE switching planes of the CX110s in slots 1E and 4E.
Figure 2-8 Mapping between the CX110 and mezz modules on compute nodes

The following describes the mapping between the CX110s and mezz modules. For example, the CX110s are installed in slots 2X and 3X and connect to Mezz 1.

Port Mapping Between a Switch Module and a Mezz Module

Mapping between the CX110 and ports on the MZ110

The MZ110 provides four GE ports, including ports 1, 2, 3, and 4. Ports 1 and 2 map to the GE switching plane of the CX110 in slot 2X, and ports 3 and 4 map to the GE switching plane of the CX110 in slot 3X.

Figure 2-9 Mapping between the CX110 and ports on the MZ110

Mapping between the CX110 and ports on the MZ111

The MZ111 provides four GE ports, including ports 1, 2, 3, and 4. Ports 1 and 3 map to the GE switching plane of the CX110 in slot 2X, and ports 2 and 4 map to the GE switching plane of the CX110 in slot 3X.

Figure 2-10 Mapping between the CX110 and ports on the MZ111