Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Other Issues

Other Issues

Table 6-1 Other issues

Error Information

Description

Handling Suggestions

Host is unreachable

The host is unreachable.

Check whether the IP address of the server to be inspected can be successfully pinged and that the configuration file is correct.

Cannot login by SSH or SFTP

The server cannot be accessed using SSH or SFTP.

  1. Check whether the SSH port is enabled and the port number is correct. For details, see GUI and Viewing and Setting BMC Port Information.
  2. On the PC running uMate, use Xshell or other software to log in to the target server over SSH or SFTP, and Check whether the login is successful.
  3. Check whether the firmware version of the target server supports uMate. For details, see Viewing BMC Versions.

User name or password error, account is locked or not an administrator.

The user cannot log in using SSH because the user name or password is incorrect, the user is locked out, or the user is not an administrator.

Check whether the user name and password are correct. Check whether the user is locked and whether the user is an administrator.

User name or password error

The user name or password is incorrect.

Check whether the user name and password are correct.

Too many authentication failures

The user cannot log in using SSH because the user is locked out.

Check the BMC health status on the BMC WebUI.

SNMP config error or unsupported server, please check the network, SNMP settings and the system configuration.

  • The SNMP configuration is incorrect or the server does not support SNMP commands.
  • The target server does not return an SNMP response.
  1. Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4.

    Check whether the server supports SNMP. For details, see Viewing and Setting BMC SNMP Protocols.

  2. Check the network communication and whether the SNMP port configuration is consistent with that on the BMC or MM910 WebUI. For details, see GUI, Viewing and Setting BMC Port Information, Viewing and Setting BMC SNMP Protocols and Viewing MM910 SNMP Protocols.

SNMP command execute failed, please check support and try again later.

An SNMP command fails to be executed.

  1. Check whether the BMC or MM configuration is correct.
  2. Try again later.

Unsupported server

The server does not support uMate.

Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4.

Username or password is invalid, can not use SNMP V3 protocol.

The user name or password does not meet SNMP requirements.

  1. Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4.

    Check whether the server supports SNMP. For details, see Viewing and Setting BMC SNMP Protocols.

  2. Check whether the password meets SNMPv3 requirements. For example, the password must contain at least eight characters.

Protocol conflict, waiting for next inspect(upgrade)...

Inconsistent SNMPv3 protocols, usernames, or passwords cause mixed inspection (upgrade).

  1. Check whether SNMPv3 protocols using by the devices are consistent.
  2. Check whether usernames and passwords for logging in to the devices are consistent.

Unable to establish LAN session, please check ipmi configuration and network.

A LAN session cannot be established, and an IPMI command fails to be executed.

  1. Manually run the IPMI command and Check whether the command execute is successful.
  2. After the command execution is successful, try again.

Task was aborted

The task is canceled.

Execute the task again.

Activate Session command failed

The command for activating a session fails.

  1. Check the network communication.
  2. Run the command again.

User must be an administrator.

The user is not an administrator.

  1. Check whether the user has administrator rights.
  2. Perform this operation as an administrator again.

Log file is not found, please try collect again later.

No log file is found during the inspection.

Collect logs separately.

Log collect fail.

Failed to collect log files during the inspection.

No space left on device, please check it and try again later.

The /tmp directory has insufficient space.

Clear the /tmp directory and collect logs again.

Network disconnected, please try collect again later.

The network is interrupted during the log collection process.

  1. Check network communication.
  2. Collect logs again.

Collect log timeout, please change the device type and try again later.

Log collection times out.

  1. Check whether the user who performs log collection is the first administrator in the BMC or HMM local user list.
  2. Collect logs again.

Permission denied, please use user "***" to collect log.

Failed to collect logs due to insufficient user permission.

Check whether the user who performs log collection is the first administrator in the BMC or HMM local user list.

Permission denied, please use the first administrator user in local user list on BMC or HMM.

Cannot login by SSH or SFTP, please execute with the manual mode.

The server cannot be accessed using SSH or SFTP.

Collect logs manually.

Download BIOS file from device failed, please try again later

The BIOS configuration file cannot be downloaded.

Try again later.

The selected template does not support this device

The selected BIOS configuration template does not support the specified server.

Select the server or a server of the same model as the template.

Upload changed file to device failed, please try it again later

The BIOS configuration file cannot be uploaded.

Try again later.

Effective BIOS configuration failed, please try again later

The BIOS configuration cannot take effect.

BIOS configuration item values do not match, this device does not support the BIOS configuration

The server does not support BIOS configuration using uMate.

Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4.

The current version of BMC does not support Boot Option settings,please upgrade to the latest version

The current BMC version of the server does not support boot option settings using uMate.

Upgrade BMC to the latest version and try again later.

The current version of BMC does not support LDAP settings,please upgrade to the latest version

The current BMC version of the server does not support LDAP configuration using uMate.

Upgrade BMC to the latest version and try again later.

This device does not support NTP settings

The server does not support NTP configuration.

Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4:

  • If yes, upgrade BMC and then try again.
  • If no, the NTP configuration is not supported.

The current version of BMC does not support Network settings,please upgrade to the latest version

The current BMC version of the server does not support network configuration using uMate.

Upgrade BMC to the latest version and try again later.

This device does not support port settings

The server does not support port number configuration.

Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4:

  • If yes, upgrade BMC and then try again.
  • If no, the NTP configuration is not supported.

The current version of BMC does not support Alarm Email settings,please upgrade to the latest version

The current BMC version of the server does not support mail server configuration using uMate.

Upgrade BMC to the latest version and try again later.

This device does not support local user security settings

The server does not support security configuration.

Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4:

  • If yes, upgrade BMC and then try again.
  • If no, the NTP configuration is not supported.

The current version of BMC does not support Time Zone settings,please upgrade to the latest version

The current BMC version of the server does not support time zone configuration using uMate.

Upgrade BMC to the latest version and try again later.

The current version of BMC does not support System settings,please upgrade to the latest version

The current BMC version of the server does not support system configuration using uMate.

Upgrade BMC to the latest version and try again later.

The current version of BMC does not support Alarm Trap settings,please upgrade to the latest version

The current BMC version of the server does not support Trap configuration using uMate.

Upgrade BMC to the latest version and try again later.

The current version of BMC does not support User settings,please upgrade to the latest version

The current BMC version of the server does not support user configuration using uMate.

Upgrade BMC to the latest version and try again later.

The current version of BMC does not support Alarm Syslog settings, please upgrade to the latest version

The current BMC version of the server does not support Syslog configuration.

Upgrade BMC to the latest version and try again later.

Please turn off the KVM connection, then try again

The KVM remote connection is not disabled.

Disable the KVM remote connection and try again.

The current version of HMM does not support NTP settings

The HMM version does not support NTP configuration using uMate.

Upgrade the HMM to the latest version and try again.

The current version of HMM does not support KVM and VMM complex settings,please upgrade to the latest version

The HMM version does not support KVM or VMM configuration using uMate.

Upgrade the HMM to the latest version and try again.

version.xml was not found in the upgrade file. Please select hpm file or upgrade on BMC web

The version.xml file cannot be found.

  • Select an .hpm file to perform an upgrade.
  • Log in to the BMC WebUI and perform the upgrade.

Upgrade file was not found, please check "FileName" node in version.xml

The upgrade file name is different from the file name configured in the version.xml file.

Change the upgrade file name in the version.xml file.

Unsupported upgrade file, that cannot find upgrade file which end with ".hpm"

The upgrade file is not in .hpm format.

Perform the upgrade on the BMC WebUI.

Get software version error

Querying firmware version failed.

Perform the server discovery again.

Upgrade abnormally, please restart BMC and try again

The BMC is stopped unexpectedly during the upgrade.

Reset the BMC. After the BMC starts, perform the upgrade again.

The target is in upgrading, please wait a few minutes and try again.

Firmware upgrade is being performed for the server.

Perform the upgrade again after the firmware upgrade is complete. It takes about 30 minutes for the firmware upgrade to complete.

Unknown upgrade error,please check BMC:1)network 2)ipmi service 3)BMC upgrade log.

An unknown upgrade error occurs.

Restart the BMC and try again. If the upgrade still fails, collect log information.

The upgrade file does not exist.

The upgrade file does not exist.

Check the upgrade file path, and perform the upgrade again.

Upgrade file error.

The upgrade file is incorrect.

Check whether the upgrade file is correct and perform the upgrade again.

The business system on power,please power off the business system and try again.

The compute node is in the power-on state and cannot be upgraded.

Power off the compute node, perform the upgrade, and power it on.

Firmware upgrade of the standby switch module is not supported.

A slave or standby switch module cannot be upgraded.

Upgrade the active switch module.

Failed to download the upgrade file.

The upgrade file cannot be downloaded.

Perform the upgrade task again.

The upgrade file error, Please confirms the upgrade file matches.

The server does not support this upgrade file for firmware upgrade.

  1. Check whether the upgrade file is correct.
  2. Download the upgrade file matching the server.

Insufficient BMC memory.The target may be upgrading, please wait a few minutes and try again.

It is detected that the memory is insufficient during firmware upgrade.

An upgrade is being performed. Wait about 30 minutes and try again. If the upgrade still fails, reset the BMC and try again.

The upgrade space is insufficient.Please restart BMC and try again.

The memory capacity is insufficient, which causes a firmware upgrade failure.

Reset the BMC and try again. If the upgrade still fails, perform the upgrade using the BMC WebUI.

Does not support the Bios 8M upgrade under the condition of power on! Please power off the server and try again

The server is in power-on state, which does not support a BIOS 8M upgrade.

Power off the server and perform the upgrade again.

Communication exception, please check the network or SNMP/IPMI configuration.

The IPMI or SNMP configuration is incorrect.

Check whether IPMI and SNMP are enabled and whether the port numbers are set correctly. For details, see GUI and Viewing and Setting BMC Port Information.

The system disk has no sufficient space.

The disk space is insufficient.

Check whether the space of the disk where uMate is located is insufficient. If yes, delete data and perform the upgrade again.

Unknown error.

An unknown upgrade error occurs.

Reset the BMC and try again.

Start upgrade failed.Plase wait 30 minutes and try again.

Failed to start the upgrade probably because an upgrade is being performed.

  • Wait 30 minutes and perform the upgrade again.
  • If the upgrade still fails, perform the upgrade using the BMC WebUI.

Upgrade timeout.

The upgrade times out.

  1. Check whether the management network communication is normal.
  2. Reset the BMC and perform the upgrade again.
  3. If the upgrade still fails, perform the upgrade using the BMC WebUI.

Sftp fw to BMC or MM failed.Please check your sftp setting and try again.

Uploading the upgrade file to server failed.

  1. Check whether the /tmp directory of the BMC or HMM has sufficient disk space. If the disk space is insufficient, delete unnecessary files and perform the upgrade again.
  2. Check whether the user has SFTP permission.
  3. Check whether the server firmware version is supported by referring to Table 1-3 and Table 1-4. For details about how to check the BMC firmware version, see Viewing BMC Versions.
  4. Check whether the SSH port is enabled and whether the port number is set correctly. For details, see GUI and Viewing and Setting BMC Port Information.
  5. Reset BMC and try again.
  6. If the upgrade still fails, perform the upgrade using the BMC WebUI.
  7. Collect logs in the log folder in the uMate tool directory, and contact Huawei technical support. For details, see Getting Help.

The BMC or HMM upgrade process is running.

The BMC or HMM upgrade is in progress.

Wait until the current upgrade is complete, and try again.

Not support bundle version information.

The current BMC or HMM version does not support access to bundle version information.

Upgrade the BMC or the HMM, and try again.

No bundle version information.

The current BMC or HMM version has no bundle version information.

Upgrade the BMC or the HMM, and try again.

No HMM bundle version information.

The HMM has no bundle version information.

Upgrade the HMM so that uMate can write HMM version information.

The current version and the bundle version(version) are not compatible.

The current firmware version is incompatible with the bundle version.

Upgrade the firmware version to the specified version in the error information.

The bundle version(version) and the HMM bundle version(version) are not compatible.

The current component bundle version is incompatible with the HMM bundle version.

Upgrade the HMM and component bundles to the same version.

Upgrade failed. Card not found.

The mezzanine card to be upgraded is not detected.

Check whether a mezzanine card is installed in the corresponding slot.

Upgrade failed. Firmware matching the OS not found.

The upgrade fails because no firmware matching the OS is found.

  1. Check whether the server is compatible with the mezzanine card or RAID controller card, and selected OS. For details, see http://support.huawei.com/onlinetoolsweb/ftca/.
  2. Check whether the firmware is of the latest version.

Upgrade failed. Driver for this mezzanine card not found.

The upgrade fails because no firmware required by the mezzanine card is found.

Upgrade failed. Firmware upgrade of this card is not supported.

The mezzanine card upgrade is not supported.

Set uMate control failed, please try again later.

Failed to set a control command.

  1. Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4.
  2. Try again later.

Set boot from CD/DVD failed, cannot upgrade Firmware, please try again later.

Failed to configure the server to boot from the DVD-ROM drive.

Control the upgrade failed, please try again later.

The control times out.

Try again later.

The device upgrade firmware timeout, please check the status manually.

The firmware upgrade times out.

Log in to the Remote Virtual Console of the server, query the system status, solve problems, and perform the upgrade again. For typical reasons, see Upgrade Timeout.

Reset the system after upgrade failed, please do it manually.

The system fails to reset automatically after the upgrade is complete.

Reset the service OS manually.

Poweron the system failed, cannot upgrade Firmware, please try again later.

The system cannot be powered on.

Contact Huawei technical support. For details, see Getting Help.

Upgrade failed. The system goes to power off status, please try upgrade again later.

An upgrade failure occurs because the system automatically powers off during the firmware upgrade process.

Reset the system failed, cannot upgrade Firmware, please try again later.

The firmware cannot be upgraded because the system fails to reset.

Try again later. If the problem persists, contact Huawei technical support. For details, see Getting Help.

Mount firmware image failed.

Failed to mount the upgrade image.

  1. Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4.
  2. Check whether the image file is mounted. If yes, unmount the file and perform this operation again.

Set firmware upgrade command failed, please try again later.

Failed to send a firmware upgrade command.

  1. Check whether the server supports uMate. For details, see Table 1-3 and Table 1-4.
  2. Try again later.

Have same connect.

Switch modules have the same SOL connection.

Disconnect the SOL connection and try again.

Mount failed. The device is already mount, please unmount it first.

The mounting operation fails because virtual media have already been mounted.

Run the unmount command to unmount the virtual media and try again.

Mount media failed. Media file-path is not exists.

The path for storing the image file does not exist.

Check whether the path for storing the image file exists.

Mount media failed. Media file-path can not read.

The mounting operation fails because the image file is unreadable.

Add the read permission and try again.

Unmount failed, no media was mounted.

The unmounting operation fails because no virtual medium is mounted.

Mount the virtual media and try again.

Unmount media failed, the device is not found in the management list.

The device has not been mounted with any virtual media.

Mount the virtual media and try again.

Query the mount status failed, the device is not found in the management list.

The device has not been mounted with any virtual media.

Mount the virtual media and try again.

Mount media failed.The path of the image file does not exist or the image file is used by other program. Therefore, the image file cannot be opened.

Failed to mount the virtual media. The file to be mounted does not exist or the file is being used by another program.

  1. Check whether the path for storing the image file exists.
  2. Check whether the image file is used by other programs.
  3. Check whether the image file supports the write function.

InnerMsgPort:port-number is already in use, please change it.

The port is in being used by another program.

Modify InnerMsgPort. For details, see CLI.

InnerMsgPort must be a number, please change it.

InnerMsgPort must be a digit.

The management list contains no device.

The device management list does not contain any device.

Add managed devices and try again.

The device management service is already stopped.

The device management service stops.

This alarm does not need to be handled.

BIOS config items init failed, please try again later.

  1. Failed to download the BIOS configuration file due to a network error.
  2. uMate earlier than V144 cannot process the product names of V5 and V3 servers properly.
  3. TLS 1.0 is disabled on the iBMC of the V5 server.
  1. Connect the client to the iBMC management network port directly, and perform the operation again.
  2. Use uMate V149 or later to perform the operation.
  3. Contact Huawei technical support. For details, see Getting Help.

Download BMC file from device failed, please try again later.

  1. Failed to download the BMC configuration file due to a network error.
  2. The current server firmware version does not support Redfish interfaces. As a result, the file cannot be downloaded.
  1. Check whether the PC and the target server BMC network are connected, and check whether the communication ports are enabled.
  2. Upgrade the server firmware to the latest version.
  3. Download the BMC configuration file again.

Download BIOS file from device failed, please try again later.

  1. Failed to download the BIOS configuration file due to a network error.
  2. The current server firmware version does not support Redfish interfaces. As a result, the file cannot be downloaded.
  1. Check whether the PC and the target server BMC network are connected, and check whether the communication ports are enabled.
  2. Upgrade the server firmware to the latest version.
  3. Download the BIOS configuration file again.

Download RAID file from device failed, please try again later.

  1. Failed to download the RAID configuration file due to a network error.
  2. The current server firmware version does not support Redfish interfaces. As a result, the file cannot be downloaded.
  3. No RAID is configured on the current server.
  1. Check whether the PC and the target server BMC network are connected, and check whether the communication ports are enabled.
  2. Check whether a RAID is configured on the current server.
  3. Upgrade the server firmware to the latest version.
  4. Download the RAID configuration file again.
Translation
Download
Updated: 2019-05-17

Document ID: EDOC1000068881

Views: 74095

Downloads: 5068

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next