FusionServer Tools 2.0 uMate User Guide 36

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Out-of-Band Upgrade Program

Out-of-Band Upgrade Program

Scenarios

Use the out-of-band upgrade program on Windows.

This program is used only in uMate. You are not advised to use it alone.

Prerequisites

Conditions

None

Data

No data preparation is required for this operation.

Procedure

  1. Enter cmd in the navigation bar of the uMate folder, press Enter, and enter dir.

    D:\uMate\FusionServer Tools-uMate-Win-Vxxx>dir 
     Volume in drive D is DataDisk 
     Volume Serial Number is C081-3EC9 
     
     Directory of D:\uMate\FusionServer Tools-uMate-Win-Vxxx 
     
    2017/10/13  16:52    <DIR>          . 
    2017/10/13  16:52    <DIR>          .. 
    2017/08/18  11:12         2,031,329 bin 
    2017/10/13  16:52    <DIR>          config 
    2017/10/13  16:52    <DIR>          help 
    2016/11/23  14:09            22,528 hwServers.xls 
    2017/06/09  09:08             3,782 hwServers.xml 
    2017/10/13  16:52    <DIR>          image 
    2017/10/13  16:52    <DIR>          jre 
    2017/10/13  16:52    <DIR>          lib 
    2017/10/13  16:52    <DIR>          log 
    2016/10/08  17:15                 0 runningFlag 
    2017/10/13  16:52    <DIR>          template 
    2017/08/09  20:14               758 tool.ini 
    2017/10/13  16:52    <DIR>          tools 
    2016/12/30  10:14           455,680 uMate.exe 
    2016/11/30  16:25             6,749 uMate.png 
    2017/07/20  14:58           431,104 uMate_CLI.exe 
                   8 File(s)      2,951,930 bytes 
                  10 Dir(s)  27,113,402,368 bytes free

  2. Run the tools\outBandUpgrade\outBandUpgrade.exe command to obtain help information, as shown in Figure C-14.

    NOTE:

    Run the ./tools/outBandUpgrade/outBandUpgrade.py command on Linux to view help information.

    Figure C-14 Help information

    Table C-2 describes the parameters of the out-of-band upgrade program.

    Table C-2 Parameter description

    Parameter

    Description

    Remarks

    username

    Specifies the server BMC/MM user name.

    The user must be a system administrator.

    password

    Specifies the server BMC/MM password.

    -

    profile.xml

    Specifies the upgrade configuration file.

    -

    restart

    Specifies whether to continue the upgrade.

    If an upgrade is stopped unexpectedly, use this parameter to continue the upgrade.

  3. Prepare the upgrade configuration file profile.xml. Figure C-15 shows an example. For details about the parameters, see Table C-3.

    Figure C-15 Upgrade configuration file
    Table C-3 Parameter description

    Parameter

    Description

    Remarks

    ProductType

    Specifies the product to be upgraded. It can be Command or E9000.

    -

    UpgradeType

    Specifies the firmware to be upgraded. It can be BMC, BIOS, or mainboard CPLD.

    -

    IP

    Specifies the iBMC IP address of the target server.

    -

    ActiveMode

    Specifies how the upgrade takes effect. At present, only 0 is supported.

    -

    FW

    Specifies the local directory in which the upgrade file is stored.

    It must be an absolute path.

    SSHPort

    Specifies the SSH port number of the target server.

    -

    IpmiPort

    Specifies the IPMI port number of the target server.

    -

    SNMPPort

    Specifies the SNMP port number of the target server.

    -

    lan

    Specifies the IPMI of the target server. It can be lan or lanplus.

    -

    NOTE:

    The profile.xml configuration file cannot contain special characters & and <. The special characters may cause errors. When editing an .xml configuration file, observe the following:

    • Avoid using special characters.
    • Use escape characters for special characters. That is, use &amp; instead of & and use &It; instead of <. The following is an example:

      Use huawei&amp;123 instead of huawei&123.

  4. Perform the upgrade, as shown in Figure C-16.

    Figure C-16 Performing the upgrade

  5. After the upgrade is complete, perform operations as prompted for the upgrade to take effect.