No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CX220 Switch Module V100R001C10 User Guide 08

This document describes the CX220 FC switch module of the E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Technical Specifications

Technical Specifications

This topic describes the physical, environmental, power, and network switching specifications of the CX220.

For details about network switching parameters about the FC switching plane, see MX210&MX220_Fabric_OS_Administrator_Guide.

Table 2-6 Technical specifications

Category

Item

Specifications

Physical specifications

Dimensions (H x W x D)

388.55 mm x 35.06 mm x 272.15 mm (15.30 in. x 1.38 in. x 10.71 in.)

Color

Silver

Weight

2.5 kg

Environmental specifications

Temperature

  • Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant)
  • Storage temperature: -40°C to +65°C (-40°F to +149°F)
  • Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)
  • Temperature change rate < 20°C/h (36°F/h)

Relative humidity

  • Operating humidity: 5% to 85%
  • Storage humidity: 5% to 95%
  • Long-term storage humidity: 30% RH to 69% RH
  • Humidity change rate < 20% RH/h

Altitude

At an altitude of 900 m (2952.72 ft), the highest operating temperature is 40°C (104°F).

When the device is used at an altitude of 900 m to 5000 m, the highest operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.24 ft).

Corrosive air pollutant

  • Corrosion rate of the copper test piece < 300 Å/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)
  • Corrosion rate of the silver test piece < 200 Å/month

Particulate pollutant

  • The ISO14664-1 Class 8 requirements are met.

    It is recommended that a professional company monitor particulate pollutants in the equipment room.

  • There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.

Input power supply

Rated input voltage

12 V DC

Power consumption

Maximum power consumption

75 W

199.7 W

Table 2-7 Network switching specifications

Item

Performance Specifications

Range

Number of ports on the panel

10

  • Two serial ports: one BMC port and one SYS port
  • Eight 8 Gbit/s FC optical ports

Port rate

4G, 8G, or 16G FC optical ports

Full duplex mode

Switching capacity (throughput)

768 Gbit/s