Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting Basic Information Using Commands

Setting Basic Information Using Commands

This topic describes how to configure the basic information about the MX220. The basic information includes the device name, status, and domain ID.

Changing the Device Name

A unique device name helps locate the device quickly on a complicated network. To change the device name for the MX220 switch module, perform the following steps:

Procedure
  1. Log in to the MX220.

    For details, see Logging In to the MX220 over a Serial Port and Logging In to the MX220 Using SSH.

  2. Run the switchname command to change the device name.

    FC_SW:admin>switchname xxxx

    xxxx indicates the device name to be set.

  3. Run the switchshow command to query the configuration.

    FC_SW:admin>switchshow 
    switchName:     xxxx 
    switchType:     51.2 
    switchState:    Online 
    switchMode:     Native 
    switchRole:     Principal 
    switchDomain: 80 
    ¡­¡­¡­¡­¡­¡­     

    switchName: xxxx indicates the result.

Setting the Device Status

To set the status of the MX220 switch module to enabled or disabled, perform the following steps:

Procedure
  1. Log in to the MX220.

    For details, see Logging In to the MX220 over a Serial Port and Logging In to the MX220 Using SSH.

  2. Run the switchenable command to enable the MX220 switch module or run the switchdisable command to disable it.

    Enabling the MX220:

    FC_SW:admin> switchenable

    Disabling the MX220:

    FC_SW:admin> switchdisable

  3. Run the switchshow command to query the configuration.

    FC_SW:admin>swicthshow 
    switchName:     xxxx       
    switchType:     51.2 
    switchState:    Offline 
    switchMode:     Native 
    switchRole:     Principal 
    switchDomain: 80 
    ¡­¡­¡­¡­¡­¡­     

    switchState: Offline indicates the result.Online indicates that the MX220 is enabled state, Offline indicates that the MX220 is disabled.

Setting a Domain ID

Reset domain IDs for FC switches on the fabric network.

Context
NOTICE:

The domain ID of each FC switch on a fabric network must be unique.

Procedure
  1. Log in to the MX220.

    For details, see Logging In to the MX220 over a Serial Port and Logging In to the MX220 Using SSH.

  2. Run the switchdisable command to disable the MX220.
  3. Run the configure command.

    FC_SW:admin>configure 
    Configure¡­ 
        Fabric parameters <yes, y, no, n>: [no]     

  4. Enter Y.
  5. Enter a domain ID.

    Domain: <1..239> [1] 2

  6. Press Enter repeatedly to retain the default values for follow-up parameters.

      R_A_TOV: <4000..120000> [10000] 
      E_D_TOV: <1000..5000> [2000] 
      WAN_TOV: <0..30000> [0] 
      MAX_HOPS: <7..19> [7] 
      Data field size: <256..2112> [2112] 
      Sequence Level Switching: <0..1> [0] 
      Disable Device Probing: <0..1> [0] 
      Suppress Class F Traffic: <0..1> [0] 
      Per-frame Route Priority: <0..1> [0] 
      Long Distance Fabric: <0..1> [0] 
      BB credit: <1..27> [16] 
     
    Insistent Domain ID Mode <yes, y, no, n>: [no] 
    Virtual Channel parameters <yes, y, no, n>: [no]  
    F-Port login parameters <yes, y, no, n>: [no] 
    Zoning Operation parameters <yes, y, no, n>: [no] 
    RSCN Transmission Mode <yes, y, no, n>: [no] 
    Arbitrated Loop parameters <yes, y, no, n>: [no] 
    System services <yes, y, no, n>: [no] 
    Portlog events enable <yes, y, no, n>: [no] 
    ssl attributes <yes, y, no, n>: [no] 
    rpcd attributes <yes, y, no, n>: [no]  
    cfgload attributes <yes, y, no, n>: [no] 
    webtools attributes <yes, y, no, n>: [no] 
    Custom attributes <yes, y, no, n>: [no] 
    System <yes, y, no, n>: [no] 
     
    WARNING: The domain ID will be changed. The port level zoning may be affected. 
    FC_SW:admin>     

  7. Run the switchenable command to enable the MX220.
  8. Run the switchshow command to query the configuration.

    FC_SW:admin>switchshow 
    switchName:     xxxx       
    switchType:     51.2 
    switchState:    Offline    
    switchMode:     Native 
    switchRole:     Principal 
    switchDomain: 2 
    ………………­

    switchDomain: 2 indicates the result.