Engineering Labels for Optical Fibers
- One is for the fiber that connects the optical interfaces on two devices.
- The other is for the fiber that connects the device and the ODF.
Labels for the Optical Fibers Connecting Devices
Meaning of the Label
Content |
Meaning |
Example |
---|---|---|
MN-B-C-D-R/T |
MN: cabinet number |
M: The cabinet rows from front to back are numbered from A to Z. N: The cabinet columns from left to right are numbered from 01 to 99. For example, A01 is the cabinet in row A and column 01. |
B: chassis number |
Numbered in bottom-up order with two digits, for example, 01. |
|
C: physical slot number |
Numbered in top-down and left-right order starting from 01. For example, 01 is the first slot at the top left of the chassis. |
|
D: optical interface number. |
Numbered in top-down and left-right order, consistent with the port sequence number on the device. | |
R: Receiving interface T: optical transmitting interface |
- |
Example of the Label
Figure 14-21 shows a sample label on an optical fiber.
- "A01-01-05-01-R" indicates that the local end of the optical fiber is connected to the optical receiving interface 01 in slot 5, chassis 01 in the cabinet in row A, column 01 in the machine room.
- "G01-01-01-01-T" indicates that the opposite end of the optical fiber is connected with optical transmitting interface 01 in slot 01, chassis 01 in the cabinet in row G, column 01 in the machine room.
Labels for the Optical Fibers Connecting the Device and an ODF
Meaning of the Labels
Content |
Meaning |
Example |
---|---|---|
MN-B-C-D-R/T |
MN: cabinet number |
For example, A01. |
B: chassis number |
Numbered in bottom-up order with two digits, for example, 01. |
|
C: physical slot number |
Numbered in top-down and left-right order starting from 01. For example, 01 is the first slot at the top left of the chassis. |
|
D: optical interface number. |
Numbered in top-down and left-right order, consistent with the port sequence number on the device. | |
R: Optical receiving interface T: optical transmitting interface |
- |
|
ODF-MN-B-C-R/T |
MN: row number and column number of an ODF |
M: The cabinet rows from front to back are numbered from A to Z. N: The cabinet columns from left to right are numbered from 01 to 99. For example, G01 is the ODF of row G and column 01. |
B: row number of the terminal device |
Range from 01 to 99, for example, 01-01. |
|
C: column number of the terminal device |
||
R: Optical receiving interface T: optical transmitting interface |
- |
Example of the Label
Figure 14-22 shows a sample label on an optical fiber.
- "ODF-G01-01-01-R" indicates that the local end of the optical fiber is connected to the optical receiving terminal in row 01, column 01 of the ODF in row G, column 01 in the machine room.
- "A01-01-05-01-R" indicates that the opposite end of the optical fiber is connected to optical receiving interface 1 in slot 05, chassis 01 in the cabinet in row A, column 01 in the machine room.