Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Log and Trap Management

Log and Trap Management

Checking Logs and Traps Reported by Devices

Procedure

  1. The following example checks whether SolarWinds receives traps from S12704-1 after an interface on it is shut down/brought up.

    [S12704-1] interface GigabitEthernet 1/1/1/2
    [S12704-1-GigabitEthernet1/1/1/2] shutdown

  2. Click ALERTS & ACTIVITY > Traps. It is found that SolarWinds receives traps indicating that the interface goes Down and the OSPF link status changes. These traps are generated after GE1/1/1/2 on S12704-1 is shut down.

  3. Bring GE1/1/1/2 on S12704-1 Up.

    [S12704-1-GigabitEthernet1/1/1/2] undo shutdown

  4. Check traps on SolarWinds. It is found that SolarWinds receives traps indicating that the interface goes Up, and the OSPF link status, LLDP neighbor status, device configuration, and MSTP topology change. These traps are generated after GE1/1/1/2 on S12704-1 is brought up.