Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
S9306E and S9312E Clustering Using CSS Cards
Context
For details about cluster configuration precautions, see "CSS Support and Version Requirements" in the Configuration Guide - Device Management.
- LE2D2VS08000 card is not hot swappable.
- When installing a copper cable, optical module, or optical fiber, you can determine that it has been installed properly after hearing a click.
- When removing a copper cable, optical module, or optical fiber, push its connector or handle slightly and then pull it out.
- Ensure that the bend radius of the copper cables or optical fibers is greater than the minimum bend rand required. For more information, see the Hardware Description.
Tools and Accessories
- ESD wrist strap or ESD gloves
- Phillips screwdriver
- Diagonal pliers
- Cable ties
- Labels
Procedure
- Wear an ESD wrist strap or ESD gloves. When wearing an ESD wrist strap, ensure that the ESD wrist strap is in a close contact with your wrist, and insert the other end in the ESD jack of a cabinet/rack.
- Install a CSS card in the subcard slot of each main control unit, as shown in (Optional) Installing a CSS Subcard or an Enhanced Flexible Service Subcard.
- Install the main control units in main control slots of the switches, as shown in Installing a Card.
- Attach number labels on both ends of the cluster cables.
- Connect the stack ports with cluster cables. Each CSS card has eight SFP+ ports, which are divided into two groups. (Group 1 includes ports 1 to 4, and group 2 includes 5 to 8.) See the following figure to connect cables between groups. Ports in a group can be connected in any sequence, but each group must have at least one cable connected. For example, any port in group 1 in chassis 1 can be connected to any port in group 1 in chassis 2.
- Switches to set up a CSS must have both active and standby MPUs installed.
- It is recommended that you connect all the CSS ports on the CSS cards.
- To connect the stack ports with optical fibers, install SFP+ optical modules on the stack ports, and then connect optical fibers to the optical modules.
- To connect the stack ports with SFP+ copper cables, directly connect the copper cables to the stack ports.
- S9306E switches are used as an example here. Cable connections between S9312E switches are the same.
- Arrange the cables, route the cables through cable management frames, and bundle them with cable ties.
Keep the cable ties used to bundle cables on the same horizontal plane as the SFP+ ports to reduce the impact of gravity on these ports.
- (Optional) Wrap redundant cables in cable management trays.
- To power on the switches, ensure that power cables and ground cables are correctly connected and then switch on the external power modules and built-in power modules in turn.