No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S9300, S9300E, and S9300X Series Switches Hardware Installation and Maintenance Guide

This document describes hardware installation procedures of the S9300, S9300E, and S9300X series switches, troubleshooting methods for common hardware faults, and switch maintenance instructions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Engineering Labels for Optical Fibers

Engineering Labels for Optical Fibers

These labels are affixed to the optical fibers that connect the optical interfaces on the boards in a chassis, or on the device boxes. There are two types of labels for optical cables:
  • One is for the fiber that connects the optical interfaces on two devices.
  • The other is for the fiber that connects the device and the ODF.

Labels for the Optical Fibers Connecting Devices

Meaning of the Label
Table 14-13 lists information on both sides of the labels affixed to the optical fibers that connect two devices.
Table 14-13  Information on labels affixed to the fibers between two devices

Content

Meaning

Example

MN-B-C-D-R/T

MN: cabinet number

M: The cabinet rows from front to back are numbered from A to Z.

N: The cabinet columns from left to right are numbered from 01 to 99.

For example, A01 is the cabinet in row A and column 01.

B: chassis number

Numbered in bottom-up order with two digits, for example, 01.

C: physical slot number

Numbered in top-down and left-right order starting from 01. For example, 01 is the first slot at the top left of the chassis.

D: optical interface number.

Numbered in top-down and left-right order, consistent with the port sequence number on the device.

R: Receiving interface

T: optical transmitting interface

-

Example of the Label

Figure 14-19 shows a sample label on an optical fiber.

Figure 14-19  Sample label on an optical fiber between two devices

The meaning of the label is listed in Figure 14-19.
  • "A01-01-05-01-R" indicates that the local end of the optical fiber is connected to the optical receiving interface 01 in slot 5, chassis 01 in the cabinet in row A, column 01 in the machine room.
  • "G01-01-01-01-T" indicates that the opposite end of the optical fiber is connected with optical transmitting interface 01 in slot 01, chassis 01 in the cabinet in row G, column 01 in the machine room.

Labels for the Optical Fibers Connecting the Device and an ODF

Meaning of the Labels
Table 14-14 shows information on both sides of labels attached to an optical fiber between a device and an optical distribution frame (ODF).
Table 14-14  Information on labels affixed to a fiber between a device and an ODF

Content

Meaning

Example

MN-B-C-D-R/T

MN: cabinet number

For example, A01.

B: chassis number

Numbered in bottom-up order with two digits, for example, 01.

C: physical slot number

Numbered in top-down and left-right order starting from 01. For example, 01 is the first slot at the top left of the chassis.

D: optical interface number.

Numbered in top-down and left-right order, consistent with the port sequence number on the device.

R: Optical receiving interface

T: optical transmitting interface

-

ODF-MN-B-C-R/T

MN: row number and column number of an ODF

M: The cabinet rows from front to back are numbered from A to Z.

N: The cabinet columns from left to right are numbered from 01 to 99.

For example, G01 is the ODF of row G and column 01.

B: row number of the terminal device

Range from 01 to 99, for example, 01-01.

C: column number of the terminal device

R: Optical receiving interface

T: optical transmitting interface

-

Example of the Label

Figure 14-20 shows a sample label on an optical fiber.

Figure 14-20  Sample label on an optical fiber between the device and the ODF

Meaning of the label in Figure 14-20
  • "ODF-G01-01-01-R" indicates that the local end of the optical fiber is connected to the optical receiving terminal in row 01, column 01 of the ODF in row G, column 01 in the machine room.