Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EMC Specifications

EMC Specifications

Table A-3 EMC specifications

Item

Specifications

Electromagnetic interference (EMI)

Conducted emission (CE)

Class A, EN300386

Radiated emission (RE)

Class A, EN300386

Harmonic current

IEC61000-3-12

Voltage fluctuation and flick

IEC61000-3-11

Electromagnetic susceptibility (EMS)

Electrostatic discharge (ESD)

IEC61000-4-2 (criterion B)

Contact discharge: 6 kV; air discharge: 8 kV

Electrical fast transient (EFT)

IEC61000-4-4 (criterion B)

AC power port: ±2 kV; DC power port: ±1 kV; signal port: ±1 kV

Radiated susceptibility (RS)

IEC61000-4-3 (criterion A)

10 V/m

Conducted susceptibility (CS)

IEC6100-4-6 (criterion A)

Power port: 10 V; signal port: 3 V

Surge immunity

IEC61000-4-5 (criterion B)

  • AC power port: differential mode: ±2 kV (8/20 µs); common mode: ±4 kV (8/20 µs)
  • DC power port: differential mode: ±2 kV (8/20 µs); common mode: ±4 kV (8/20 µs)
  • Signal port: differential mode: 0.5 kV (8/20 µs); common mode: 1 kV (8/20 µs)

Voltage dips immunity (DIP)

IEC61000-4-11