Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Protocol Flapping Occurs When the CPOS Card of the AR Is Interconnected

Protocol Flapping Occurs When the CPOS Card of the AR Is Interconnected

This section provides a case that protocol flapping occurs when the CPOS card of the AR is interconnected.

Networking

Fault Symptom

PPP is configured on the CPOS card of the AR. When 64 member interfaces of two ends are bound to an MP group, protocol flapping occurs frequently.

Fault Analysis

The number of bound member interfaces exceeds the maximum value. By default, a maximum of 32 PPP links can be bound in an MP link.

If more than 32 member interfaces are added to an MP group, member interfaces that cannot be bound will go Down. These member interfaces then perform LCP renegotiation and attempt to be bound to the MP group. The unbound member interfaces alternate between Up and Down states frequently.

Run the ppp mp max-bind 32 command to bind 32 member interfaces to an MP group. Protocol flapping is removed and the fault is rectified.

Suggestion

  • After running the ppp mp max-bind command, run the shutdown and undo shutdown or restart commands to restart all the member interfaces to make the configuration take effect.
  • Generally, the maximum number of links in an MP group does not need to be set because PPP performance may deteriorate after the ppp mp max-bind command is used. Use the ppp mp max-bind command under the instruction of Huawei technical support personnel.