No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

AR Router Troubleshooting Guide

This Product Documentation provides guidance for maintaining AR Enterprise Router, covering common information collection and fault diagnostic commands, typical fault troubleshooting guide, and troubleshooting.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
A Card Fails to Register After a Software Upgrade

A Card Fails to Register After a Software Upgrade

Fault Description

A card works normally in the old system software version. After the system software is upgraded, the card indicator is steady red, and the card fails to register.

  • If a card registers successfully, the Register field in the display device command output displays Registered.
    <Huawei> display device                                                    
    AR3260's Device status:                                                          
    AR3260-S's Device status:                                                          
    Slot    Sub Type    Online    Power      Register      Alarm      Primary  
     5      8FE1GE     Present    PowerOn   Registered    Normal         NA    
  • If the card fails to register, the Register field displays Unregistered.
    <Huawei> display device                                                    
    AR3260's Device status:                                                          
    AR3260-S's Device status:                                                          
    Slot    Sub Type    Online    Power      Register      Alarm      Primary  
     5      8FE1GE     Present    PowerOn   Unregistered    NA           NA    

Possible Causes

  • The card was removed and reinstalled before the upgrade but was not securely connected to the backplane.

  • The card software is upgraded after the system software is upgraded. During the card software upgrade, the router is powered off, causing an upgrade failure.

Troubleshooting Procedure

  1. Remove the card and check whether any pins on the backplane connector are bent. Ensure that the card can be securely connected to the backplane.
    NOTE:

    Use a flashlight when checking the backplane connector.

  2. Contact technical support personnel through Collecting Information and Contacting Technical Support and restore the card software under their help.

    A card software upgrade takes about 8 minutes. Ensure that the router is not powered off during the upgrade.