Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Changed BFD Session Parameters Do Not Take Effect

Changed BFD Session Parameters Do Not Take Effect

Common Causes

This fault is commonly caused by the following:
  • After parameters of a BFD session have been changed, changed configurations are not committed.

Troubleshooting Flowchart

Figure 23-5  Troubleshooting flowchart for the fault that the changed BFD session parameters do not take effect

Troubleshooting Procedure

Context

NOTE:

Save the results of each troubleshooting step. If your troubleshooting fails to correct the fault, you will have a record of your actions to provide Huawei technical support personnel.

Procedure

  1. Run the display current-configuration configuration bfd-session command to check that the commit command is configured.

    • If the commit command is configured, the changed BFD session parameters have been committed. Then, go to Step 3.

    • If the commit command is not configured, the changed BFD session parameters have not been committed. Then, run the commit command, and then go to Step 2.

  2. Run the display bfd session all command check whether the BFD session parameters are specified values.

    • If BFD session parameters are specified, the modified parameters take effect.

    • If BFD session parameters are not specified, go to Step 3.

  3. If the fault persists, collect the following information and contact technical support personnel.

    • Results of the preceding troubleshooting procedure.
    • Configuration files, log files, and alarm files of the devices.

Translation
Download
Updated: 2019-05-10

Document ID: EDOC1000079719

Views: 450742

Downloads: 4309

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next